Table 8.3:
Level 3
Leuze electronic
Digital SWIO submenu
Level 4
Level 5
Switching
Inverted
output
Signal delay
Pulse duration
Activation function 1
Deactivation function 1 See Activation function 1 for selection
BCL 500
Display and control panel
Selection/configuration option
Description
OFF / ON
OFF = activated switching output
upon high level
ON = activated switching output upon
low level
Value from 0 to 65535
Time in milliseconds between activa-
tion function and switching of the
switching output.
Value from 0 to 65535
Switch-on time of the switching output
in milliseconds. If the Pulse duration is
set to 0, the switching output is
switched on via the Activation function
and switched off via the Deactivation
function.
If the Pulse duration is greater than 0,
the Deactivation function has no
effect.
No function
Reading gate start
Reading gate end
Positive reference code comparison 1
Negative reference code comparison 1
Valid read result
Invalid read result
Device ready
Device not ready
Data transmission active
Data transmission not active
AutoCont. good quality
AutoCont. bad quality
Reflector detected
Reflector not detected
External event, pos. edge
External event, neg. edge
Device active
Device standby
No device error
Device error
Positive reference code comparison 2
Negative reference code comparison 2
The function set here specifies which
event activates the switching output.
options
The function set here specifies the
event that deactivates the switching
output.
i
i
\ BCL 501
Standard
OFF
0
400
No function
No function