Leuze electronic BCL500i Technical Description page 131

Hide thumbs Also See for BCL500i:
Table of Contents

Advertisement

Online commands
Manual definition of the reference code
Command
Description
Parameter
Acknowledge-
ment
Example
128
This command can be used to define a new reference code in the
BCL 500
i
by means of direct input via the serial interface. The data is
saved in the parameter set according to your input under reference
code 1 through 2 and stored in the working buffer for direct further
processing.
'RSyvxxzzzzzzzz'
y, v, x and z are placeholders (variables) for the actual input.
y
Defined reference code no.
'1'
(Code 1)
'2'
(Code 2)
v
Storage location for reference code:
'0'
RAM+EEPROM,
'3'
RAM only
xx
Defined code type (see command 'CA')
z
Defined code information (1 ... 63 characters)
'RSx'
x
Status
'0'
Valid 'Rx' command
'1'
Invalid command
'2'
Insufficient memory for reference code
'3'
Reference code has not been saved
'4'
Reference code invalid
Input = 'RS130678654331' (Code 1 (1), RAM only (3), UPC (06), code
information)
i
BCL 500
RS
i
\ BCL 501