Leuze electronic BCL500i Technical Description page 20

Hide thumbs Also See for BCL500i:
Table of Contents

Advertisement

Select the desired interface standard (RS 232 / RS 422) and set the associated commu-
nication parameters:
• Via webConfig:
Configuration -> Communication -> HOST/BUS IN -> Data transmission
Select the desired communication protocol and set associated parameters:
• Via webConfig:
first
Configuration -> Communication -> HOST/BUS IN -> Protocol
Operation as a multiNet plus slave
Notice!
The BCL
501i
default address is 1.
The Leuze multiNet plus permits an address range from 0 to 31. Address 31 must not be
used for data communication. It may only be used temporarily for commissioning.
Set the Slave address parameter to a value > 0 and < 31. Start with address 01 for the
first slave and assign further addresses in contiguous ascending order.
• Via webConfig:
Configuration -> Communication -> BUS OUT -> Protocol
Further settings
After the basic configuration of the operating mode and the communication parameters, you
need to carry out further settings:
• Decoding and processing the read data
Define at least one code type with the desired settings.
• Via webConfig:
Configuration -> Decoder
• Control of the decoding
Configure the connected switching inputs according to your requirements. To do
this, first set the I/O mode to Input and then configure the switching behaviour:
• Via webConfig:
Configuration -> Device -> Switching inputs/outputs
• Control of the switching outputs
Configure the connected switching outputs according to your requirements. To do
this, first set the I/O mode to Output and then configure the switching behaviour:
• Via webConfig:
Configuration -> Device -> Switching inputs/outputs
Leuze electronic
always automatically starts as a slave participant in the multiNet plus. The
BCL 500
Fast commissioning / operating principle
i
i
\ BCL 501
17