Figure 4.9: Scanner Arrangement With The Multiscan Function - Leuze electronic BCL500i Technical Description

Hide thumbs Also See for BCL500i:
Table of Contents

Advertisement

Device description
always process two readings for a single packet, i.e. a decoding result and a No Read, a
multiScan arrangement is used which transmits only one reading from the two read stations
to the host; this single reading is transmitted by the multiScan master.
Notice!
Thus, from the perspective of the host, the scanner network appears to be just a single bar-
code reader!
For this purpose one multiScan master and one or more multiScan slaves are connected
together via the RS 485 interface.
Figure 4.9:
Scanner arrangement with the multiScan function
Notice!
The multiScan function on the RS 485 interface is possible for minimum of 2 and a maxi-
mum of 32 devices!
The protocol set on the RS 485 interface is the multiNet protocol. As a result, during multi-
Scan operation on the RS 485 interface, the multiNet master also functions as the
multiScan master and the multiNet slaves function as multiScan slaves (thus, all multiNet
slave are included in multiScan operation).
i
i
Leuze electronic
BCL 500
\ BCL 501
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl501i

Table of Contents