Module 65 - Deflection Mirrors; Switching Inputs/ Outputs Swio 1; Parameters For Operating As An Output - Leuze electronic BCL548i Manual

Table of Contents

Advertisement

Commissioning and configuration
10.12.6 Module 65 – Deflection mirrors
PROFINET-IO module identifier
Module-ID
Submodule-ID
Description
Module for supporting the deflection mirror.
Parameter
Parameter
Deflection angle
Table 10.42:
Parameter length
2 bytes
Input data
None
Output data
None

10.13 Switching inputs/ outputs SWIO 1 ... 4

These modules define the mode of operation of the 4 digital switching inputs and outputs
(I/Os). They are separated into individual modules for configuring the individual I/Os and a
shared module for signaling the status and controlling all I/Os.

10.13.1 Parameters for operating as an output

Start-up delay
With this setting, the output pulse can be delayed by the specified time (in ms).
Switch-on time
Defines the switch-on time period for the switching input. Any activated switch-off function
then no longer has any function.
A value of 0 causes the output to be set statically; this means that the selected input func-
tion(s) activate the output, and the selected switch-off function(s) deactivate it again.
176
1065
1
Description
Lateral beam exit in degrees relative to
the zero position
Parameters for module 65
Addr.
Data type
0 ...1
SIGNED16
BCL
548i
Value range
Default
-100 ... +100
0
Leuze electronic
Unit
1/10°

Advertisement

Table of Contents
loading

Table of Contents