Reference-code teach-in
Command
Description
Parameter
Acknowledge-
ment
Notice!
With this function, only code types are recognised that are identified using the autoConfig
function or which were set in the set-up.
After each reading via an 'RTy' command, explicitly switch off the function again since
failure to do so will interfere with other commands as well as prevent execution of a new
'RTx' command.
Leuze electronic
This command enables a reference code to be defined quickly by read-
ing an example label.
'RTy'
y
Function
'1'
Defines reference code 1
'2'
Defines reference code 2
'+'
Activates the definition of reference code 1 up to the
value of Parameter no_of_labels
'-'
Exits the Teach-In process
The BCL 500
i
\ BCL 501
corresponding status (see command 'RS'). After a barcode has been
read, it sends the result in the following format:
'RCyvxxzzzzz'
y, v, x and z are placeholders (variables) for the actual input.
y
Defined reference code no.
'1'
(Code 1)
'2'
(Code 2)
v
Memory location for reference code
'0'
RAM+EEPROM,
'3'
RAM only
xx
Defined code type (see command 'CA')
z
Defined code information (1 ... 63 characters)