Summary of Contents for Leuze electronic BCL 80

  • Page 1 Leuze electronic Bar Code Reader BCL 80 with Integrated Decoder Connector Unit MA 10 Technical Description Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 2 All rights reserved, especially the rights of production, distribution and translation. Duplication or reproduction in any form (print, photo- copies, microfilm or data) may only be carried out with the expressed written consent of Leuze electronic GmbH + Co. We reserve the right to make changes for the technical improvement of the product...
  • Page 3: Table Of Contents

    Proper Configuration of the Devices .................. 27 Connection .........................29 6.4.1 Connecting the BCL 80 for ’Stand Alone’ Operation..............30 6.4.2 Connecting the BCL 80 with the Connector Unit MA 10 .............. 32 6.4.3 Wire Lengths and Shielding......................39 6.4.4 Disassembling, Packing, Disposing..................... 39...
  • Page 4 9.1.4 ’Online’ Commands for Querying Statistical Data ................56 9.1.5 ’Online’ Commands for Parameter Set Operations ..............57 9.1.6 ’Online’ Commands for BCL 80 with Oscillating Mirror..............58 Setup Program ........................60 9.2.1 Overview of the Parameter Structure ...................60 9.2.2 Setting the Decoding Parameters ....................63 9.2.3...
  • Page 5: General Information

    "fragments." Deactivation End a read process, e.g. by using an online command. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 6 Bar code reader that optically scans the bar code with a laser beam. Switched output Connection for output of status or event messages, e.g. after a failed read. Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 7: Declaration Of Conformity

    Teach-In Programming a reference code using an example bar code. Declaration of Conformity The bar code reader BCL 80 and the connector unit MA 10 have been developed and produced in accordance with the applicable European standards and directives. Note! The corresponding declaration of conformity can be requested from the manufacturer.
  • Page 8: Safety Notices

    The connector and interface unit MA 10 simplifies the connection of the bar code reader of type BCL 80 / BCL 40 and adapts to various host interfaces. Connection to other bar code readers is not authorised.
  • Page 9: Organisational Measures

    Mounting, commissioning and maintenance of the device may only be carried out by qualified person- nel. Electrical work must be carried out by a certified electrician. Repair Repairs must only be carried out by the manufacturer or an authorised representative. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 10: Description

    Description The Bar Code Readers BCL 80 The bar code reader BCL 80 is a high-speed scanner with integrated decoder for all bar codes cur- rently in use, e.g. 2/5 Interleaved, EAN, etc. The many possible configurations of the device allow its adaptation to a multitude of reading tasks.
  • Page 11 IP 65 are fulfilled when using this cable only (see Chapter 5)! BCL 80 with MA 10 When using several BCL 80 units or under rough environment conditions, the installation of one con- nector unit MA 10 for each BCL 80 unit is recommended.
  • Page 12 Description Networking Up to 31 BCL 80 bar code readers can be networked together using the connector unit MA 10 (with interface module RS 485). The devices are interconnected by connecting the individual RS 485 inter- faces in parallel.
  • Page 13: Construction

    4 fastening threads M4 on the device the rear of the device Reading window Dovetail fastening 15 pin SubD connector groove Figure 3.3: Bar code reader BCL 80 Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 14 Leuze electronic Description Device construction MA 10 Mounting holes for the 4 Status-LEDs BCL 80 with M4 screws on the rear Screw gland PG11 for the power supply cable Screw glands PG9 for the switched input and the inter- face cables...
  • Page 15: Technical Data

    General Technical Data Manufacturer: Leuze electronic GmbH + Co.,In der Braike 1, D-73277 Owen / Teck Type: BCL 80, bar code reader with integrated decoder MA 10, connector / interface unit for BCL 80 Technical Data BCL 80 General Specifications...
  • Page 16 Storage temperature range -20 … +60°C Air humidity max. 90% rel. humidity, non-condensing Vibration accord. to IEC 68.2.6 Shock accord. to IEC 68.2.27 accord. to IEC 801 Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 17: Dimensioned Drawings

    M4 - 10 deep (4 x) 149.2 Figure 4.1: Dimensioned drawing BCL 80 171.5 Figure 4.2: Dimensioned drawing of BCL 80 with oscillating mirror add-on 22.5 M 4 (4x) Figure 4.3: Dimensioned drawing MA 10 Leuze electronic Technical Description BCL 80...
  • Page 18: Optical Data

    Technical Data Optical Data The range in which the bar code can be read by the BCL 80 (the so-called reading field) depends on the quality of the printed bar code and its dimensions. Therefore, above all, the module of a bar code is decisive for the size of the reading field.
  • Page 19: Type Overview

    500 36450 BCL 80 O1 L 100 1800 500 36451 BCL 80 CRT M 100 1600 500 29025 BCL 80 CRT O1 M 100 1400 500 36452 BCL 80 R1 M 100 1600 500 29221 Line Scanner Single Line (1 line)
  • Page 20: Reading Fields

    The BCL 80 is available in two different versions (with / without oscillating mirror add-on) that also dif- fer in range and resolution (see Chapter 4.3.1). Version S (BCL 80 S N1 100 / BCL 80 S N2 100 / BCL 80 S M 100 / BCL 80 S L 100): Standard version with / without CRT Medium to very long range for barcodes with a medium module.
  • Page 21: Scanning Curves Of The Bcl 80

    Leuze electronic Technical Data 4.3.4 Scanning curves of the BCL 80 BCL 80 S N1 100 BCL 80 S N2 100 m = 0.5 m = 0.3 1000 -100 -100 m = 0.3 m = 0.2 -200 -150 -300 -200...
  • Page 22 Leuze electronic Technical Data BCL 80 O N2 100 BCL 80 O N2 100 vertical horizontal at +15˚/-20˚ +15˚ m = 0.5 m = 0.3 m = 0.5 m = 0.3 -100 -100 -150 -150 -200 -200 -250 -250 -300 -300 -20˚...
  • Page 23: Accessories / Order Designation

    Accessories / Order Designation Addresses for ordering Products from Leuze electronic GmbH + Co. can be ordered from any of the sales and serv- ice offices listed on the back page of this operating manual. Connector and interface unit MA 10...
  • Page 24 Figure 5.2: Mounting device BT 57 Mounting device BT 58 Rotating joint, suitable for Item MB system Mounting plate for mounting to the BCL 80 with screws Figure 5.3: Mounting device BT 58 Type Short Description Part No.
  • Page 25: Cable Accessories

    15-conductor connection cable BCL 80 / MA 10, Sub D plug and socket xxxx = Length in mm Figure 5.4: Connection cable between the BCL 80 and MA 10 KB 040-xxxx-B 15-conductor connection cable, Sub D socket with open strand ends for connecting in switch-...
  • Page 26: Installation

    • Observe the applicable local regulations when disposing of the packaging materials. Cleaning • Clean the glass window of the BCL 80 with a soft cloth before mounting. Remove any remaining packaging from the device such as cardboard fibres and Styrofoam balls, particularly in the area of the connector socket.
  • Page 27: Mounting

    Mounting example BCL 80 'stand alone' Mounting BCL 80 and MA 10 You can fasten the scanner BCL 80 and connector unit MA 10 tightly together to form a single com- pact unit. • Plug the two devices together at the 15 pin SubD connector. Be sure that there is no dirt in the area of the seal (this guarantees an IP 65 protection class).
  • Page 28 Mounting example for the combined BCL 80 / MA 10 unit Independent mounting BCL 80 / MA 10 Independent mounting of the BCL 80 and MA 10 is necessary when • the available mounting depth is not sufficient for both devices, e.g. is less than 85 mm, or •...
  • Page 29: Proper Configuration Of The Devices

    You can mount the individual devices in the following way as already described above: • using the dovetail groove of the BCL 80 or the MA 10 and the corresponding mounting accessories • using the fastening threads on the back- or underside of the devices •...
  • Page 30 • it is rotated by 5 … 20° around its vertical axis. Large depth of focus Due to the large reading distance and the large depth of focus, the BCL 80 is especially suited for ap- plications with varying goods or reading distances.
  • Page 31: Connection

    MA 10 / opt. sensor Host interface Figure 6.7: Application example ’Packet conveyor belt’ Due to the great depth of focus, the BCL 80 is ideally suited for packet and pallet transportation appli- cations. Connection Attention! Connection of the device and maintenance work while under voltage must only be carried out by a qualified electrician.
  • Page 32: Connecting The Bcl 80 For 'Stand Alone' Operation

    6.4.1 Connecting the BCL 80 for ’Stand Alone’ Operation If you would like to connect the BCL 80 for ’stand alone’ operation, you must make a corresponding connector cable with a 15 pin SubD plug (female) for the following connections: •...
  • Page 33 MA 10: service interface, standard protocol Pin 14 MODE_S RS 232: open; RS 485: connect with MODE_F Pin 15 GND_IN Supply voltage 0 V DC Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 34: Connecting The Bcl 80 With The Connector Unit Ma 10

    Leuze electronic Installation 6.4.2 Connecting the BCL 80 with the Connector Unit MA 10 Connection of the BCL 80 is considerably easier when using the MA 10. Sensor, Voltage supply Button Switching output BCL 80 Host interface RS 232, RS 485...
  • Page 35 Terminal strip Attached label with the terminal names Cable screw glands PG9 and PG11 Figure 6.13: Position of the connections for the MA 10 Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 36 485A 485B 485B not used RS 485 Interface Host interface module shield shield max. 1200m Figure 6.14: Connecting the MA 10 to a RS 485 Host Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 37 Host interface module shield Jumper Jumper Ground (shield) max. 1000m Jumper position passive Figure 6.17: Connecting the MA 10 as passive subscriber to a TTY Host Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 38 1, connection A SE1_B switching input 1, connection B VDD_SE supply voltage, switching input, equal to V_IN device GND_SE supply voltage, switching input, equal to GND_IN device Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 39 Leuze electronic Installation Supply voltage MA 10 / BCL 80 18 … 36 V MA 10 External Optically coupled switched input switching voltage to processor Figure 6.19: Connection of the switching input with an external switching voltage Supply voltage MA 10 / BCL 80 18 …...
  • Page 40 Optically coupled switched input VDD_SA SA1/2 from processor GND_SA solder jumper open GND_IN MA 10 Figure 6.23: Switching voltage connected externally (galvanically decoupled) Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 41: Wire Lengths And Shielding

    SMD-LEDs that illuminate when the respective switching output is in the HI state (log.1). Please note that the event which sets the switching outputs must be set and activated in the software setup of the BCL 80. Supply voltage...
  • Page 42: Commissioning

    - 0, if the combined BCL 80 / MA 10 unit will not be operated in a network, - 1 … 31, if several BCL 80 / MA 10 units will be operated in a network. Each multiNet plus net- work device must have a different device address assigned to it.
  • Page 43 Note! If the BCL 80 is to be operated as a ’stand alone’ device, a reset is only possible via software. There is a small green LED inside the BCL 80 at the lower edge of the reading window that displays the operation readiness.
  • Page 44: Function Test

    Leuze service office (see last page of this operating manual). Setting the Parameters Three different parameter sets are maintained by the MA 10 when using the BCL 80 / MA 10 com- bined unit: • the factory default parameter set •...
  • Page 45 In this parameter set, the current settings for all device parameters are stored. If the BCL 80 is in 'stand alone' operation, the parameter set is stored in the EEPROM of the BCL 80. If an MA 10 is also used,...
  • Page 46: Service Operating Mode

    A PC or terminal can be connected to the MA 10 via the RS 232/V.24 serial interface and used to set the parameters of the BCL 80. The connection is made using a crossed RS 232 connection cable that establishes the RxD, TxD and GND connections. The hardware handshake at the service interface is via RTS.
  • Page 47 In setting 2 (’operation’) of the operating mode switch, the terminal connector can be used as a data monitor. In this case, data sent from the BCL 80 (jumper in Figure 7.1 in upper po- sition) or data received from host (jumper in Figure 7.1 in lower position) can be logged. The data protocol is set by the host interface in the latter case.
  • Page 48: Setting Parameters 'Offline' (Loading)

    This causes the required parameters to be transferred from the host computer, or a computer con- nected to the interface terminal of the MA 10, to the BCL 80 or MA 10, respectively. If the same pa- rameters are to be loaded into several devices, parameter download is the most efficient method.
  • Page 49: Setting The Bar Code Parameters Using 'Autoconfig

    Number of labels to be decoded While 'autoConfig' is active, have the BCL 80 read as many labels in row as it will later during a reading cycle when in normal operation. The number of labels can be set from 'Set Code' in the submenu 'De- coding' of the setup program.
  • Page 50: Operation

    ’cold start’ reset (> 4 s) up until the reset button is released. All four LEDs blink • if the connection between the MA 10 and BCL 80 is interrupted. RDY blinks • during the 'Power On' function test.
  • Page 51: Important Functions During Operation

    Operation Important Functions During Operation The BCL 80 has a function which automatically monitors the reading quality as well as the quality of the bar code label. ’autoControl’ function When the ’autoControl’ function is active, the BCL 80 constantly compares the total number of scans with the number of decoded scans.
  • Page 52: Configuration

    ’Online’ commands can be used to send commands directly to the device for diagnosis and configu- ration. In order to use this feature, the BCL 80 /MA 10 must be connected to a host or service compu- ter via the serial interface. The commands can be sent either via the host or the service interface.
  • Page 53: General 'Online' Commands

    Read/write operations cannot be carried out in the service mode. The setup program must always be ended (see Chapter 9.2.1), in order to return to normal operation. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 54 ’RS’ Description This command can be used to define a new reference code in the BCL 80 by means of direct entry via the serial interface. The data are saved in the parameter set according to their input under reference code 1 or 2 and stored in the working buffer for further processing.
  • Page 55 Reads the code type and contents of an unknown label without storing it in Setup. Parameter none Acknowledgement xx yy zzzzzz Description The acknowledgement is the same as that of the ’autoConfig’ function. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 56: Online' Commands For System Control

    Deactivates the definition of reference code 1 (sensor input 2). A signal can be simulated on sensor input 2 with this command. Parameter none Acknowledgement none Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 57: Online' Commands For System Testing

    Description xxxxx is the current rotary frequency of the motor in revolutions/minute. Supply voltage Command ’DUV’ Description Returns the supply voltage of the BCL 80. Parameter none Acknowledgement ’DUVxx.x’ Description xx.x is the current supply voltage in V. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 58: Online' Commands For Querying Statistical Data

    ’ST17XXXXX’: XXXXX is the number of read enables since the last reset ’ST18XXXXX’: XXXXX the number of correctly decoded labels since the last reset ’ST19XXXXX’: XXXXX the number of incorrectly decoded labels since the last reset Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 59: Online' Commands For Parameter Set Operations

    Example ’0’ current parameter set. ’2’ parameter set with factory default settings. ’PC20’: Reset to factory default settings Parameter BCL 80 with MA 10: Examples ’0’ current parameter set. ’1’ customer-specific parameter set. ’2’ parameter set with factory default settings.
  • Page 60: Online' Commands For Bcl 80 With Oscillating Mirror

    Leuze electronic Configuration 9.1.6 ’Online’ Commands for BCL 80 with Oscillating Mirror Attention! The ’PT’ command lets you change the parameter set in a way that may render it useless. Make sure that you only use parameter numbers and ranges that have been described here.
  • Page 61 Acknowledgement ’xx’ = current value from the parameter’s range of values (e.g. 03h) Example Input = ’PR00387001’ returns the value for the current setting of the reverse movement time (e.g. ’0A’) Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 62: Setup Program

    3: Error Character [‘&‘] 4: Warning Character [‘@‘] ⇐ Additional Functions 1: Reference Code Command ’ x ’ 2: AutoControl (exit setup) Figure 9.1: Overview of the parameter structure Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 63 • Save and Quit: saves the new settings in the current parameter set and exits the setup program. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 64 Host Interface’ ’ 3: Digital IN/OUT’ ’ 4: General’ ’ 5: Additional Functions’ ’ ’ ’Enter:’ The individual menu points of the 'Decode Setup' are described below. Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 65: Setting The Decoding Parameters

    Use the 'CA' or 'CC' command to avoid mistakes. • A code type can be deselected by setting its number of characters to the value '0'. Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 66 Output formatting The menu 'Output Format' is more extensive and is therefore discussed later in its own section (see Chapter 9.2.3 "Setting the Output Format Parameters"). Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 67: Setting The Output Format Parameters

    You can select the following submenus in the menu ’Output Format’: • Formatter modes • Title headers • Label headers • Label footers • Output constants Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 68 No. of All Scans of the gate time Nothing Header 2 Title Header char 1 No. of Valid Labels No. of All Scans of the gate time Other entries on request Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 69 Other entries on request Label Footer Three footer texts can be specified in the menu 'Label Footer': • Label Footer 1 • Label Footer 2 • Label Footer 3 Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 70 20 characters [18H] Note! The characters can be entered as decimal code, hexadecimal code or as a character. Char- acters set to ’00H’ are not output! Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 71: Setting The Host Interface Parameters

    9 Bit, no parity, 1 stop bit multiNet mode Baudrate baud baud baud 1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud 57600 baud Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 72 BCC mode 3 More detailed information concerning the BCC modes is available on request. Note! If the BCL 80 should operate ’stand alone’ as a slave in the multiNet, then the following set- tings are required: Data format: multiNet mode...
  • Page 73: Setting The Parameters Of The Digital In/Out

    3964 / RK 512 Protocol The BCL 80 / MA 10 can be operated with the procedure 3964 / RK 512. For this the option ’3964 / RK 512 protocol’ must be activated in the menu ’General Settings / Protocol’. The required parameters are set in the menu ’3964 / RK 512’.
  • Page 74 Enable Yes, No [Yes] Activation Good Read Bad Read Start Reading Stop Reading Device Ready autoControl Reference code 1 Reference code 2 Inversion Yes, No [No] Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 75: Setting The General Parameters

    • Decoder address: A decoder address must be set if the BCL 80 is to be operated without an MA 10 in the multiNet, thus no address switch is available. Here the option 'Host interface / frame protocol / ASCII address' must be activated.
  • Page 76: Additional Functions: Setting The Reference Code Parameters

    When a reference code is defined, the 'Don't care' character is not taken into account Example: Code 1: Code Info: 1234**** By setting the 'Don't-Care' character, the affected positions are "ignored", i.e. they are not relevant to the code comparison. Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 77: Additional Functions: Setting The 'Autocontrol' Parameters

    It can be any ASCII character. Parameter Valid range of values Default Character for AutoControl warning all ASCII characters ['!'] 00: no output via the serial interface Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 78: Maintenance

    Maintenance 10.1 General Maintenance Information The bar code reader BCL 80 and the connector unit MA 10 normally should not require any mainte- nance by the user. Cleaning Should it become soiled, clean the glass window of the BCL 80 with a soft cloth.
  • Page 79: Appendix

    NUMBER SIGN Nummerzeichen DOLLAR SIGN Dollarzeichen PERCENT SIGN Prozentzeichen & AMPERSAND Kommerzielles UND-Zeichen APOSTROPHE Apostroph OPENING PARENTHESIS runde Klammer (offen) CLOSING PARENTHESIS runde Klammer (geschlossen) ASTERISK Stern Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 80 Kommerzielles a-Zeichen Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Großbuchstabe Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 81 Kleinbuchstabe Kleinbuchstabe Kleinbuchstabe Kleinbuchstabe OPENING BRACE geschweifte Klammer (offen) VERTICAL LINE Vertikalstrich CLOSING BRACE geschweifte Klammer (zu) TILDE Tilde DELETE (RUBOUT) Löschen Table 11.1: ASCII Table Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 82: Example Bar Code Lable Types

    Leuze electronic Appendix 11.2 Example Bar Code Lable Types 11.2.1 Module 0.5 Figure 11.1: Barcode sample labels (module 0.5) Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 83 Leuze electronic Appendix Figure 11.2: Barcode sample labels (module 0.5) - continued Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 84: Module 1.0

    Leuze electronic Appendix 11.2.2 Module 1.0 Figure 11.3: Barcode sample labels (module 1.0) Technical Description BCL 80 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 85 Leuze electronic Appendix Figure 11.4: Barcode sample labels (module 1.0) - continued Leuze electronic Technical Description BCL 80 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...

This manual is also suitable for:

Ma 10

Table of Contents