10.3.3 Control of the switching outputs

By using the switching inputs/outputs of the BCL 500
functions can be implemented without assistance from the primary process control. For this
purpose, the respective connection at the SW IN/OUT and POWER interfaces must be
configured as a switching output.
A switching output can be activated:
• at the start/end of the reading gate
• depending on the read result:
reference code comparison positive/negative
read result valid/invalid
• depending on the state of the device:
ready/not ready
data transmission active/not active
active/standby
error/no error
• etc.
As described in chapter 7 of the manual , connect the required switching outputs of the
BCL
500i
Configure the connected switching outputs according to your requirements. To do this,
first set the I/O mode to Output and then configure the switching behaviour:
• Via webConfig:
Configuration -> Device -> Switching inputs/outputs
• Or, alternatively, via the display
Parameter -> Digital SWIO -> Switching input/output 1-4
Leuze electronic
\ BCL 501i.
BCL 500
Commissioning and configuration