Intel Agilex Configuration User Manual page 93

Hide thumbs Also See for Agilex:
Table of Contents

Advertisement

5. Remote System Update
UG-20205 | 2019.04.03
Command
Code
(Hex)
5B
RSU_STATUS
(10)
This number does not include the command and response header.
Send Feedback
Command
Response
(10)
(10)
Length
Length
1
2
3
4
5
0
8
Reports the current remote system update status. This command returns the following responses:
Word
0-1
2-3
4
Description
0xF006
0xF007
Version
0 for this version.
Pin status
Specifies the values of the following configuration control signals.
Bit [31]: Current
nSTATUS
Bit [30]: Detected
nCONFIG
Bit [29:3]: Reserved.
Bit [2:0]: The
MSEL
Soft function
Specifies the value of each of the soft functions, whether you assigned the
status
function assigned to an SDM pin.
Bit [31:4]: Reserved.
Bit [3]:
SEU_ERROR
Bit [2]:
.
CVP_DONE
Bit [1]:
INIT_DONE
Bit [0]:
CONF_DONE
Error location
Contains the error location. Returns 0 for no error.
Error details
Contains the error details. Returns 0 for no error.
Summary
Description
Current
Flash offset of the currently running application image.
image
First failing
Flash offset of the first failing application image. A value of all 1s indicates
image
no failing images. When there are no failing images, the following words do
not contain meaningful data.
State
Failure code of the last failing image.
The error field has two parts:
HPS_WATCHDOG_TIMEOUT
INTERNAL_UNKNOWN_ERROR
output value (active low).
input value (active low).
value at power up.
.
.
.
Intel
®
Agilex
Configuration User Guide
continued...