72–8
Slide Motor
Counter–
clockwise
Front Vertical
Motor
Counter–
clockwise
Lifter Motor
Counter–
clockwise
AVENSIS REPAIR MANUAL (RM1018E)
SEAT
4.
INSPECT POWER SEAT MOTOR ASSY
(a)
Inspect operation of the slide motor.
(1)
Clockwise
Standard:
Driving Axis
Battery positive voltage " 1
Battery negative voltage " 2
B65859
Battery positive voltage " 2
Battery negative voltage " 1
If the result is not as specified, replace the motor assy.
(b)
Driver side seat:
Inspect operation of the front vertical motor.
(1)
Clockwise
Standard:
Battery positive voltage " 1
Driving Axis
Battery negative voltage " 2
B65859
Battery positive voltage " 2
Battery negative voltage " 1
If the result is not as specified, replace the motor assy.
(c)
Driver side seat:
Inspect operation of the lifter motor.
Clockwise
(1)
Standard:
Battery positive voltage " 1
Driving Axis
Battery negative voltage " 2
B65859
Battery positive voltage " 2
Battery negative voltage " 1
If the result is not as specified, replace the motor assy.
http://vnx.su
–
FRONT POWER SEAT CONTROL SYSTEM
Check that the motor rotates smoothly when the
battery is connected to the motor connector termi-
nals.
Tester Connection
Check that the motor rotates smoothly when the
battery is connected to the front vertical motor con-
nector terminals.
Tester Connection
Check that the motor rotates smoothly when the
battery is connected to the lifter motor connector
terminals.
Tester Connection
Operational Direction
Clockwise
Counterclockwise
Operational Direction
Clockwise
Counterclockwise
Operational Direction
Clockwise
Counterclockwise