Attach the Samtec BullsEye connector to the GTH Quad 115
indexing pins on the bottom of the connector with the guide holes on the board. Hold the
connector flush with the board and fasten it by tightening the two captive screws.
X-Ref Target - Figure 1-5
Figure 1-5: BullsEye Connector Attached to GTH Quad 115
GTH Transceiver Clock Connections
See
inputs. Connect these cables to the SuperClock-2 module as follows:
•
•
Note:
the GTH reference clock. CLKOUT1_P and CLKOUT1_N are used here as an example.
VC7222 IBERT Getting Started Guide
UG971 (v5.0) June 12, 2014
Figure 1-2
to identify the P and N coax cables connected to the CLK0 reference clock
CLK0_P coax cable → SMA connector J5 (CLKOUT1_P) on the SuperClock-2 module
CLK0_N coax cable → SMA connector J6 (CLKOUT1_N) on the SuperClock-2
module
Any one of the five differential outputs from the SuperClock-2 module can be used to source
www.xilinx.com
Running the GTH IBERT Demonstration
(Figure
1-5), aligning the two
Send Feedback
11