6.2 MACHINE PERSONALITY SETTINGS

FUNCTION
DRIVE
STEER
SWING
3121714
Table 6-4. Personality Ranges/Defaults
PERSONALITY
ACCELeration
DECELeration
DECELeration to stop
MAXimum Forward speed
REDUCED MAXimum speed MAXimum Reverse Drive
ELEVATED MAXimum speed (ANSI)
ELEVATED MAXimum speed (CE)
CREEP MAXimum speed
ACCELeration
DECELeration
MINimum LEFT speed
MAXimum LEFT speed
MINimum RIGHT speed
MAXimum RIGHT speed
ACCELeration
DECELeration
MINimum LEFT speed
MAXimum LEFT speed
CREEP Maximum LEFT speed
MINimum RIGHT speed
MAXimum RIGHT speed
CREEP maximum RIGHT speed
SECTION 6 - JLG CONTROL SYSTEM
NOTE: Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.
RANGE
0.5s to 5.0s
0.3s to 5.0s
0.3s to 2.0s
75 to 100%
50 to 74%
5 to 15%
5 to 15%
5 to 15%
0.1 to 5.0s
0.1 to 5.0s
20 to 40%
50 to 90%
20 to 40%
50 to 90%
0.1 to 5.0s
0.1 to 5.0s
1 to 15%
36 to 80%
16 to 35%
1 to 15%
36 to 80%
16 to 35%
DEFAULTS
2.0s
3.0s
1.0s
100%
60%
7%
7%
7%
2.0s
0.3s
20%
60%
20%
60%
2.5s
2.5s
1%
60%
20%
1%
60%
20%
6-13