6.7 CALIBRATING LOAD SENSING

NOTE: Calibration sub-menu LOAD SENSING is visible only if
MACHINE SET-UP sub-menu LOAD SYSTEM is selected to
NO.
1. Position the Platform/Ground select switch to the Plat-
form position.
2. Plug the analyzer into the connector at the base of the
platform control box.
3. Pull out the Emergency Stop switch and Start the
engine.
4. The analyzer screen should read:
5. Use the arrow button to reach ACCESS LEVEL. Hit Enter.
6. Enter the Access Code, 33271.
7. Use the right Arrow key to reach CALIBRATIONS. Hit
Enter.
3121714
SECTION 6 - JLG CONTROL SYSTEM
8. Use the arrow keys to reach LOAD SENSING. The screen
will read:
9. Hit Enter. The screen will read:
6-55