DTC Cat
DTC Num
99
252
REAR RIGHT MODULE - WATCHDOG2 RESET
99
253
REAR RIGHT MODULE - RAM FAILURE
99
254
REAR RIGHT MODULE - INTERNAL ERROR
99
255
REAR RIGHT MODULE - INTERNAL ERROR
99
256
REAR RIGHT MODULE - INTERNAL ERROR
99
257
REAR RIGHT MODULE - INTERNAL ERROR
99
258
REAR RIGHT MODULE - INTERNAL ERROR
99
259
REAR RIGHT MODULE - INTERNAL ERROR
99
260
REAR RIGHT MODULE - CAPACITOR BANK FAULT The power capacitor bank of the Power Module is
99
261
REAR RIGHT MODULE - A/D FAILURE
99
264
REAR LEFT MODULE - CURRENT MEASURE-
MENT ERROR
99
265
REAR RIGHT MODULE - CURRENT MEASURE-
MENT ERROR
99
270
REAR RIGHT MODULE - DRIVE COMMAND
ERROR
99
269
REAR LEFT MODULE - DRIVE COMMAND ERROR Power Modules determine that an inconsistency
99
273
FUNCTIONS LOCKED OUT – REAR LEFT MODULE
SOFTWARE VERSION IMPROPER
3121714
Table 6-17. Diagnostic Trouble Codes
DTC Text
Applicable Power Module determines that
Watchdog2 failure/reset has occurred
Applicable Power Module determines that a RAM
checksum error has occurred
Applicable Power Module determines at Startup
that the current gain is incorrect and may cause
incorrect data acquisition values
Applicable Power Module determines that the data
acquisition is in error
Applicable Power Module determines that the
Pump current is being measured is not zero when
expected to be zero at Startup or during standby
Applicable Power Module determines that the Slip
Profile is in error
Applicable Power Module determines that the cur-
rent feedbacks are out of range at Startup or when
in standby
Applicable Power Module determines at Startup
that there is a problem with overvoltage/under-
voltage detection
not charging properly (increasing voltage) at
Startup
Applicable Power Module determines that an
internal Analog Input error exists
Power Module determines at when traction is
active that the current feedback sensors are out of
the permitted range and may cause incorrect data
acquisition values
Power Module determines at when traction is
active that the current feedback sensors are out of
the permitted range and may cause incorrect data
acquisition values
Power Modules determine that an inconsistency
has occurred between the Drive direction/enable
bits and Drive magnitude/direction command
has occurred between the Drive direction/enable
bits and Drive magnitude/direction command
The UGM software version type is 'P' The UGM has
received valid version information from all Power
Modules. The Power Module major version number
is not compliant with the version specified on the
Software section of this document.
SECTION 6 - JLG CONTROL SYSTEM
Fault Description
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Not all of the trigger conditions are met
Solution