JLG E450A Service And Maintenance Manual page 394

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
DTC Cat
DTC Num
42
32
REAR LEFT MOTOR TOO HOT - PLEASE WAIT
42
33
REAR RIGHT MOTOR TOO HOT - PLEASE WAIT
44
1
BATTERY VOLTAGE TOO LOW - SYSTEM SHUT-
DOWN
44
2
BATTERY VOLTAGE TOO HIGH - SYSTEM SHUT-
DOWN
44
3
LSS BATTERY VOLTAGE TOO HIGH
44
4
LSS BATTERY VOLTAGE TOO LOW
44
20
BATTERY DEEPLY DISCHARGED
44
30
BATTERY VOLTAGE TOO LOW
44
63
REAR LEFT MODULE - VOLTAGE OUT OF RANGE
44
64
REAR RIGHT MODULE - VOLTAGE OUT OF RANGE Associated Power Module determines System
46
92
REAR LEFT BRAKE - SHORT TO GROUND OR
OPEN CIRCUIT
46
93
REAR RIGHT BRAKE - SHORT TO GROUND OR
OPEN CIRCUIT
46
100
REAR LEFT BRAKE RETURN - SHORT TO BATTERY Traction Module detects an overcurrent condition
6-78
Table 6-17. Diagnostic Trouble Codes
DTC Text
The UGM determines that the drive motor temper-
ature reported by the PM > 140°C but < 200 °C or
the PM determines that motor temperature sensor
is reporting > 150°C
UGM to suppress if DTC 4228 is active.
The UGM determines that the drive motor temper-
ature reported by the PM > 140°C but < 200 °C or
the PM determines that motor temperature sensor
is reporting > 150°C
UGM to suppress if DTC 4229 is active.
The UGM detects that its 12V supply voltage is less
than 9.0 volts for 5 seconds.
The UGM detects that its 12V supply voltage > 16.0
volts
MACHINE SETUP -> LOAD SYSTEM ≠ NO; The UGM
determines that LSS error bit is set for supply volt-
age too high (> 34.0V)
MACHINE SETUP -> LOAD SYSTEM ≠ NO; The UGM
determines that LSS error bit is set for supply volt-
age too low (< 9.0V)
UGM determines that the SOC% related to the Bat-
tery has reached the Deeply Discharged condition.
Based on SOC% only, not Voltage threshold; No
audible annunciation for this DTC.
UGM detects that its supply voltage < 11 volts for 5
seconds.
Associated Power Module determines System
Overvoltage/Undervoltage, Voltage measurement
≥ 65V or ≤ 12V
Overvoltage/Undervoltage, Voltage measurement
≥ 65V or ≤ 12V
Associated Power Module detects A4 shorted to
ground: at Standby as or at Running (PWM Supple-
mental info not applicable to this DTC for initiating
separate DTC: Power Module detects A4 shorted to
ground at Startup as or Power Module detects A2
shorted to ground only at Startup, not detected in
Standby or Running.
Associated Power Module detects A4 shorted to
ground: at Standby as or at Running (PWM Supple-
mental info not applicable to this DTC for initiating
separate DTC: Power Module detects A4 shorted to
ground at Startup as or Power Module detects A2
shorted to ground only at Startup, as not detected
in Standby or Running.
on pin A4, indicating a short between B+ and the
Electric Brake FET
Fault Description
Power Module no longer report fault and UGM
determines motor temp ≤ 140 °C (149-10 °C) and
Controls initialized.
Drive disable reset when motor temp ≤ 139 °C
(149-10 °C)and Drive Joystick in Neutral.
Power Module no longer report fault and UGM
determines motor temp ≤ 140 °C (149-10 °C) and
Controls initialized.
Drive disable reset when motor temp ≤ 139 °C
(149-10 °C)and Drive Joystick in Neutral.
UGM voltage > 9.25V
Power cycle
Not all of the trigger conditions are met; motion
restrictions removed after controls initialized
Not all of the trigger conditions are met; motion
restrictions removed after controls initialized
Power cycle
UGM voltage > 11.25V
Traction modules no longer report fault then
controls initialized.
Traction modules no longer report fault then con-
trols initialized.
Power cycle
Power cycle
Power cycle
Solution
3121714

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450aM450ajE450aj

Table of Contents