JLG E450A Service And Maintenance Manual page 392

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
DTC Cat
DTC Num
33
110
TOWER LIFT DOWN VALVE - OPEN CIRCUIT
33
111
TOWER LIFT DOWN VALVE - SHORT TO BATTERY The UGM detects a short to ground at the tower lift
33
118
SWING RIGHT VALVE - SHORT TO GROUND
33
119
SWING RIGHT VALVE - OPEN CIRCUIT
33
120
TELESCOPE IN VALVE - SHORT TO BATTERY
33
122
SWING LEFT VALVE - SHORT TO GROUND
33
123
TELESCOPE OUT VALVE - SHORT TO BATTERY
33
175
JIB ROTATE LEFT VALVE - OPEN CIRCUIT
33
176
JIB ROTATE LEFT VALVE - SHORT TO BATTERY
33
177
JIB ROTATE LEFT VALVE - SHORT TO GROUND
33
178
JIB ROTATE RIGHT VALVE - OPEN CIRCUIT
33
179
JIB ROTATE RIGHT VALVE - SHORT TO BATTERY
33
180
JIB ROTATE RIGHT VALVE - SHORT TO GROUND
33
182
LIFT VALVES - SHORT TO BATTERY
33
186
TELESCOPE OUT VALVE - OPEN CIRCUIT
33
188
TELESCOPE OUT VALVE - SHORT TO GROUND
33
189
TELESCOPE IN VALVE - OPEN CIRCUIT
33
190
TELESCOPE IN VALVE - SHORT TO GROUND
33
295
SWING LEFT VALVE - OPEN CIRCUIT
33
298
STEER LEFT - SHORT TO GROUND
33
305
STEER RIGHT - SHORT TO GROUND
33
314
FLOW CONTROL VALVE - OPEN CIRCUIT
6-76
Table 6-17. Diagnostic Trouble Codes
DTC Text
The UGM detects an open circuit supporting the
Tower Down Solenoid
down output
The UGM detects a short to ground at the Swing
Right output
The UGM detects an open circuit at the Swing Right
output
The UGM detects a short to 12V battery at this out-
put
The UGM detects a short to ground at the Swing Left
output
The UGM detects a short to 12V battery at this out-
put
MACHINE SETUP -> JIB PLUS = YES;
UGM detects an open circuit at the jib rotate left
output
MACHINE SETUP -> JIB PLUS = YES;
UGM detects a short to ground at the jib rotate left
output
MACHINE SETUP -> JIB PLUS = YES;
UGM detects a short to battery at the jib rotate left
output
MACHINE SETUP -> JIB PLUS = YES;
UGM detects an open circuit at the jib rotate right
output
MACHINE SETUP -> JIB PLUS = YES;
UGM detects a short to battery at the jib rotate right
output
MACHINE SETUP -> JIB PLUS = YES;
UGM detects a short to ground at the jib rotate right
output
UGM detects a short to 12V battery at either the Lift
Up or Lift Down valve
UGM detects an open circuit at this output
The UGM detects a short to ground at this output
The UGM detects an open circuit at this output
The UGM detects a short to ground at this output
The UGM detects an open circuit at the Swing Left
output
The UGM detects a short to ground at steer left out-
put.
The UGM detects a short to ground at steer right
output.
The UGM detects an OC at this output
Fault Description
UGM no longer detects open circuit;
Inhibits and restrictions removed after CntrlIni;
Power cycle
Power cycle
UGM no longer detects OC;
Speed restrictions removed after CntIni
Power cycle
Power cycle
Power cycle
UGM no longer detects OC;
Speed restrictions removed after CntIni
Power cycle
Power cycle
UGM no longer detects OC;
Speed restrictions removed after CntIni
Power cycle
Power cycle
Power cycle
UGM no longer detects OC.
Speed restrictions removed after CntIni
Power cycle
UGM no longer detects OC.
Speed restrictions removed after CntIni
Power cycle
UGM no longer detects OC;
Speed restrictions removed after CntIni
Power cycle
Power cycle
Power cycle
Solution
3121714

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450aM450ajE450aj

Table of Contents