JLG E450A Service And Maintenance Manual page 400

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
DTC Cat
DTC Num
99
234
REAR LEFT MODULE - EEPROM FAILURE
99
235
REAR LEFT MODULE - PROTECTION FAILURE
99
236
REAR LEFT MODULE - CHECK POWER CIRCUITS
OR MOSFET SHORT CIRCUITC
99
237
REAR LEFT MODULE - WATCHDOG RESET
99
238
REAR LEFT MODULE - WATCHDOG2 RESET
99
239
REAR LEFT MODULE - RAM FAILURE
99
240
REAR LEFT MODULE - INTERNAL ERROR
99
241
REAR LEFT MODULE - INTERNAL ERROR
99
242
REAR LEFT MODULE - INTERNAL ERROR
99
243
REAR LEFT MODULE - INTERNAL ERROR
99
244
REAR LEFT MODULE - INTERNAL ERROR
99
245
REAR LEFT MODULE - INTERNAL ERROR
99
246
REAR LEFT MODULE - CAPACITOR BANK FAULT
99
247
REAR LEFT MODULE - A/D FAILURE
99
248
REAR RIGHT MODULE - EEPROM FAILURE
99
249
REAR RIGHT MODULE - PROTECTION FAILURE
99
250
REAR RIGHT MODULE - CHECK POWER CIRCUITS
OR MOSFET SHORT CIRCUIT
99
251
REAR RIGHT MODULE - WATCHDOG RESET
6-84
Table 6-17. Diagnostic Trouble Codes
DTC Text
Applicable Power Module determines at Startup
that an internal EEPROM error exists or UGM fails to
successfully verify or write to/read back Indirect
Table three times
Applicable Power Module determines that an
internal failure exists in the hardware protection
circuit
Applicable Power Module determines at Startup
that a short circuit exists on the power MOSFET out-
puts
Applicable Power Module determines that Watch-
dog failure/reset has occurred to one if two, or both
Applicable Power Module determines that
Watchdog2 failure/reset has occurred
Applicable Power Module determines that a RAM
checksum error has occurred
Applicable Power Module determines at Startup
that the current gain is incorrect and may cause
incorrect data acquisition values
Applicable Power Module determines that the data
acquisition is in error
Applicable Power Module determines that the
Pump current is being measured is not zero when
expected to be zero at Startup or during standby
Applicable Power Module determines that the Slip
Profile is in error
Applicable Power Module determines that the cur-
rent feedbacks are out of range at Startup or when
in standby
Applicable Power Module determines at Startup
that there is a problem with overvoltage/under-
voltage detection
The power capacitor bank of the Power Module is
not charging properly (increasing voltage) at
Startup
Applicable Power Module determines that an
internal Analog Input error exists
Applicable Power Module determines at Startup
that an internal EEPROM error exists or UGM fails to
successfully verify or write to/read back Indirect
Table three times
Applicable Power Module determines that an
internal failure exists in the hardware protection
circuit
Applicable Power Module determines at Startup
that a short circuit exists on the power MOSFET out-
puts
Applicable Power Module determines that Watch-
dog failure/reset has occurred to one if two, or both
Fault Description
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Solution
3121714

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450aM450ajE450aj

Table of Contents