Table 3-5. Controller Interface Pin Assignments
PIN
30
+ Output voltage
31
Speed sensing + 5V
32
Output current sense
33
Not used
34
Not used
35
Field Drive

Warnings and Safety Precautions

THE RBS MAY START WITHOUT WARNING.
MORE THAN ONE LIVE CIRCUIT IS USED INSIDE THE RBS CONTROL PANEL.
EXERCISE CAUTION WHEN THE CONTROL PANEL IS OPEN, EVEN WHEN THE
RBS IS NOT RUNNING.

System Controls

INHIBIT RUN INPUT
The inhibit run input prevents the RBS from starting, clears
any existing calls to start and stops the engine immedi-
ately. To return to normal operating mode, the inhibit run
input must be removed.
MANUAL CALL TO START
The manual call to start input initiates an automatic run of
the RBS unit.
RS232 PORT
The RS232 allows the RBS to be monitored and controlled
using an analyzer.

System Status and Performance Monitoring

System status and performance can be monitored by the
analyzer.
3121714
FUNCTION
SECTION 3 - CHASSIS & TURNTABLE

System Settings

CALL TO START SETTINGS
Low battery voltage call to start level
Low battery voltage remove call to start level
Low temperature call to start level
Low temperature remove call to start level
Low start battery voltage call to start level
Low start battery voltage remove call to start level
CURRENT AND VOLTAGE SETTINGS
Normal output voltage level
Extend output voltage level
Current limit level
High voltage shutdown level
Finish charging current level
TIME DELAY SETTINGS
TD engine start
TD purge
TD bypass
TD engine run
TD cool-down
TD high volts
CRANK SETTINGS
Crank time
Reset time
Crank cycles
SPEED TIME AND GLOW PLUG SETTINGS
TD no speed signal
TD DC sensing fault
Starter disconnect
Overspeed shutdown
Underspeed shutdown
Glow plug on temperature
Glow plug on time
48.0 VDC
54.0 VDC
5°C
8°C
12.2 V
12.9 V
58.0 VDC
58.0 VDC
45 ADC
63 ADC
30 ADC
30s
0s
10s
1800s
30s
2s
15s
15s
3
5s
10s
1000 Hz
3800 RPM
2000 RPM
5°C
15s
3-69