Platform Level Up Relief

1. Install the pressure gauge at the "B2" port on the back of
the Main Control Valve, activate and bottom out Plat-
form Level Up.
2. Adjust Platform Level Up Relief to value given in Figure
5-151., Main Valve Pressure Adjustment.
3121714
SECTION 5 - BASIC HYDRAULIC INFORMATION & SCHEMATICS

Platform Level Down Relief

1. Install the pressure gauge at the "B1" port on the back of
the Main Control Valve, activate and bottom out Plat-
form Level Down.
2. Adjust Platform Level Down Relief to value given in Fig-
ure 5-151., Main Valve Pressure Adjustment.