JLG E450A Service And Maintenance Manual page 364

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Message Displayed on
Analyzer
CHECKING PLATFORM INPUTS
6-48
Table 6-11. System Test Messages
Message Displayed on
Analyzer
PLATFORM RT VALVE
PLATFORM LEVEL UP
PLATFORM LEVEL DOWN
HEAD/TAIL LIGHTS
VOTE RELAY
DRIVE MAX SPEED
DRIVE REDUCED SPEED
CL PLATFORM UP
OP PLATFORM UP
CL PLATFORM DOWN
OP PLATFORM DOWN
LIFT JOYSTICK TO UP MAX
LIFT JOYSTICK TO DOWN MAX
SWING JOYSTICK TO LEFT MAX
SWING JOYSTICK TO RIGHT MAX
CREEP SWITCH CCW
CREEP SWITCH CW
FUNC SPD TO MAX
FUNC SPD TO MIN
CL HORN
OP HORN
CL PLATFORM LEFT
OP PLATFORM LEFT
CL PLATFORM RGHT
OP PLATFORM RGHT
CL TOWER UP
OP TOWER UP
CL TOWER DOWN
OP TOWER DOWN
CL JIB UP
OP JIB UP
CL JIB DOWN
OP JIB DOWN
CL JIB LEFT
OP JIB LEFT
CL JIB RIGHT
OP JIB RIGHT
CL TELE IN
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay); dis-
played if the head/tail light option is configured.
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay); dis-
played if the head/tail light option is configured.
OPEN or CLOSED (advance after switch closed to open)
OPEN or CLOSED (advance after switch closed to open)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
(wait for joystick to reach +100% then advance)
(wait for joystick to reach -100% then advance)
(wait for joystick to reach -100% then advance)
(wait for joystick to reach +100% then advance)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles) (E300, E400)
OPEN or CLOSED (advanced test after switch toggles) (E300, E400)
OPEN or CLOSED (advanced test after switch toggles) (E300, E400)
OPEN or CLOSED (advanced test after switch toggles) (E300, E400)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
OPEN or CLOSED (advanced test after switch toggles)
Description
3121714