Machine Personality Settings - JLG 600A Service And Maintenance Manual

Table of Contents

Advertisement

6.8 MACHINE PERSONALITY SETTINGS

FUNCTION
DRIVE
TOWER LIFT
UPPER LIFT
3121201
Table 6-1. Personality Ranges/Defaults
PERSONALITY
ACCELeration
DECELeration
Forward MINimum speed
Forward MAXimum speed
REVerse MINimum speed
REVerse MAXimum speed
ELEVATED MAXimum speed
CREEP MAXimum speed
Engine RPM
ACCELeration
DECELeration
MlNimum UP speed
MAXimum UP speed
MINimum DOWN speed
MAXimum DOWN speed
Engine RPM
ACCELeration
DECELeration
MlNimum UP speed
MAXimum UP speed
CREEP Maximum UP speed
MINimum DOWN speed
MAXimum DOWN speed
CREEP maximum DOWN speed
Engine RPM
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
RANGE
0.1s to 5.0s
0.1s to 3.0s
0 to 35%
0 to 100%
0 to 35%
0 to 100%
0 to 50%
0 to 50%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 60%
0 to 100%
0 to 60%
0 to 100%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 60%
0 to 100%
0 to 65%
0 to 60%
0 to 100%
0 to 75%
800 to 2900
DEFAULTS
2.0
2.0
4
35
4
22
10
25
1800
1.0
0.5
50
100
50
100
1800
2.0
0.7
30
55
55
40
65
55
1800
6-17