SECTION 9 - JLG CONTROL SYSTEM
tem
will
calculate
personalities).
12. After completing the Relief Valve calibration, hit ESC
twice to go back to CALIBRATIONS.
13. Control the different pressures and adjust the per-
sonality settings if required (refer to § 9-9 for person-
ality settings adjustment procedures): see Table 9-2
for the acceptable pressure values.
Function
Minimum pressure
Mast Lift Up
16 MPa
Jib Lift Up
14 MPa
Swing Right / Left
4 MPa
Steer Right
7 MPa
Steer Left
10 MPa
Table 9-2. Acceptable Pressure Values
9-8
and
overwrite
all
MAXP
Maximum Pressure
2320 psi
18 MPa
2610 psi
2030 psi
16 MPa
2320 psi
580 psi
5 MPa
725 psi
1015 psi
9 MPa
1305 psi
1450 psi
12 MPa
1740 psi
9.9 MACHINE PERSONALITY -
ADJUSTMENT SETTINGS
Personality settings adjustments shall be done when the
system is idle (none of the power components, drive or
pump motor, is running).
Each time the Up or Down arrow is hit to modify a person-
ality setting, the value is modified in the Master Module
memory and written in the Slave Module memory. If a per-
sonality value is changed by maintaining the Up or Down
arrow, the value set in the Master Module is the value dis-
played but the value written in the Slave Module may dif-
fer: in this situation, the altered movement speed or
pressure will NOT be consistent with the displayed value.
In order to ensure that the verification of the modified set-
ting is valid:
• Values should be changed step by step, or
• The last value adjustment should be a single step
adjustment, or
• The power should be cycled.