SECTION 3 - CHASSIS & TURNTABLE
3.10 SUPPLEMENTARY FUSE FOR APU
The purpose of this section is to describe the procedure to
add a supplementary fuse for the Engine Generator Con-
troller for the APU.
Tools And Material
• - Weather proof fuse holder - JLG PN 2400081
• - AGC1, 1 Amp fuse - JLG PN 2400080
• - 45 cm of #16 AWG wire - JLG PN 4920019
• - 2 X insulated butt splice connectors - JLG PN 4460035
• - 6 X medium length wire ties - JLG PN 4240033
• - Wire/Side cutters
• - 5/32" Allen Key
• - Crimping tool
Procedure
BEFORE BEGINNING THIS PROCEDURE, ENSURE THAT ALL SOURCES OF
POWER ARE DISCONNECTED FROM THE APU!
This procedure is common for all applications of the APU.
The photos contained in this document illustrate the modi-
fication performed to an APU supplied in a JLG M450 lift.
1. Locate the harness at the rear of the APU.
3-74
2. where the harness attaches to the rear cover of the gen-
erator and the connection point for the new inline fuse.
3. Remove the socket head drive screw with a 5/32" Allen
key. Next remove the cable clamp from the harness.
3121714