Machine Personality Settings - JLG 600SJC Service And Maintenance Manual

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM

6.2 MACHINE PERSONALITY SETTINGS

FUNCTION
DRIVE
TOWER LIFT
UPPER LIFT
6-14
Table 6-2. Personality Ranges/Defaults
PERSONALITY
ACCELeration
DECELeration
Forward MINimum speed
Forward MAXimum speed
REVerse MINimum speed
REVerse MAXimum speed
ELEVATED MAXimum speed
CREEP MAXimum speed
Engine RPM
ACCELeration
DECELeration
MlNimum UP speed
MAXimum UP speed
MINimum DOWN speed
MAXimum DOWN speed
Engine RPM
ACCELeration
DECELeration
MlNimum UP speed
MAXimum UP speed
CREEP Maximum UP speed
MINimum DOWN speed
MAXimum DOWN speed
CREEP maximum DOWN speed
Engine RPM
– JLG Lift –
NOTE: Personality settings can be adjusted within the adjustment
range for optimum machine performance.
RANGE
0.1s to 5.0s
0.1s to 3.0s
0 to 35%
0 to 100%
0 to 35%
0 to 100%
0 to 50%
0 to 50%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 60%
0 to 100%
0 to 60%
0 to 100%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 60%
0 to 100%
0 to 65%
0 to 60%
0 to 100%
0 to 75%
800 to 2900
DEFAULTS - 600S
2.0
2.0
4
35
4
35
15
25
1800
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2.0
0.7
40
80
55
40
70
55
1800
3121607

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600sc

Table of Contents