JLG E450A Service And Maintenance Manual page 395

Table of Contents

Advertisement

DTC Cat
DTC Num
46
130
MAIN CONTACTOR / REAR RIGHT BRAKE
RETURN - SHORT TO BATTERY
46
104
REAR LEFT SPEED SENSOR - NOT RESPONDING
PROPERLY
46
105
REAR RIGHT SPEED SENSOR - NOT RESPONDING
PROPERLY
46
108
REAR LEFT SPEED SENSOR - RPM HIGH
46
109
REAR RIGHT SPEED SENSOR - RPM HIGH
46
136
REAR LEFT BRAKE SUPPLY VOLTAGE – OUT OF
RANGE LOW
46
137
REAR RIGHT BRAKE SUPPLY VOLTAGE – OUT OF
RANGE LOW
66
2
CANBUS FAILURE - PLATFORM MODULE
66
3
CANBUS FAILURE - LOAD SENSING SYSTEM
MODULE
66
13
CANBUS FAILURE - EXCESSIVE CANBUS ERRORS UGM observes more than 22 error frames per sec-
66
35
CANBUS FAILURE - CHASSIS TILT SENSOR
66
54
CANBUS FAILURE - REAR LEFT MODULE
66
55
CANBUS FAILURE - REAR RIGHT MODUL
66
57
CANBUS FAILURE - TEMPERATURE SENSOR
77
25
PUMP MOTOR - NOT RESPONDING
3121714
Table 6-17. Diagnostic Trouble Codes
DTC Text
At Startup, the Master Traction Module detects an
overcurrent condition on pin A12, indicating a
short between B+ and the Main Contactor.
During active traction, the Master Traction Module
detects an overcurrent condition on pin A4. Electric
Brake FET
Associated Power Module has detected an encoder
or directional sensing problem
Associated Power Module has detected an encoder
or directional sensing problem
Associated Power Module determines an over-
speed condition (measured motor speed > DRIVE
MAX + 15Hz) has occurred on a motor
Associated Power Module determines an over-
speed condition (measured motor speed > DRIVE
MAX + 15Hz) has occurred on a motor
Associated Power Module determines that a low
parking brake supply voltage condition exists.
Associated Power Module determines that a low
parking brake supply voltage condition exists.
UGM does not receive any CAN messages from Plat-
form Module in 250ms
MACHINE SETUP -> LOAD SYSTEM ≠ NO;
UGM does not receive any CAN messages from the
LSS module in 1000ms
ond for 4 seconds or more than 500 Buss Off condi-
tions since last power cycle.
UGM does not receive any CAN1 messages from
Chassis Tilt Sensor in 250ms
After Startup complete, Power Module CAN2 mes-
sages are not received in 200ms
After Startup complete, UGM or Power Modules not
receive the designated CAN messages in 200ms
(250ms for UGM)
UGM determines that:
• MACHINE SETUP TEMP CUTOUT = YES
• UGM does not receive any CAN1 messages from
the Low Temperature Cutout sensor in 250ms
Suppress DTCs 241 and 242 if this DTC is active.
The Master Traction Module detects that the pump
motor feedback is not responding when the pump
is being commanded
SECTION 6 - JLG CONTROL SYSTEM
Fault Description
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
Power cycle
CAN1 messages are received from the PM and
controls are initialized
Not all of the trigger conditions are met; motion
restrictions removed after controls initialized
Power cycle
CAN1 messages are received from the sensor and
controls are initialized;
UGM receives all traction modules CAN2 mes-
sages and shall command main contactor closed;
once fault reset, motion permitted after controls
are initialized.
If CAN messages are lost more than 5 times, the
fault shall be latched until Power Cycle.G352
UGM receives all traction modules CAN2 mes-
sages and shall command main contactor closed;
once fault reset, motion permitted after controls
are initialized.
If CAN messages are lost more than 5 times, the
fault shall be latched until Power Cycle.
UGM receives CAN1 messages from the Ambient
Temperature sensor; speed restrictions removed
after controls initialized
Power cycle
Solution
6-79

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450aM450ajE450aj

Table of Contents