JLG E450A Service And Maintenance Manual page 360

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Diagnostics Submenu
(Displayed on Analyzer
st
1
Line)
JIB LIFT UP SW
JIB LIFT DN SW
JIB SWING LT SW
JIB SWING RT SW
PLAT LEVEL UP SW
PLAT LEVEL DN SW
PLAT ROT LEFT SW
PLAT ROT RGHT SW
MAX SPEED SW
CREEP SW
HORN SW
SG OVERRIDE SW
MSSO SW
OPTIONS
H&T LIGHTS SW
H&T LIGHTS OUT
SKYGUARD INPUTS
SKYGUARD INPUT 1
SKYGUARD INPUT 2
SOFTTOUCH INPUT
6-44
Table 6-9. DIAGNOSTICS - Menu Descriptions
Parameter
(Displayed on
st
Analyzer 1
Line)
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
ON/OFF
OPEN/CLOSED/DISAGREE
OPEN/CLOSED
OPEN/CLOSED
OPEN/CLOSED
Parameter Value
(Displayed on
nd
Analyzer 2
Line)
Status of Ground/Platform Toggle Switch Input
[MACHINE SETUP ' Jib = YES]
Status of Ground/Platform Toggle Switch Input
[MACHINE SETUP ' Jib = YES]
Status of Ground/Platform Toggle Switch Input
[MACHINE SETUP ' Jib Swing = YES]
Status of Ground/Platform Toggle Switch Input
[MACHINE SETUP ' Jib Swing = YES]
Status of Ground/Platform Toggle Switch Input
Status of Ground/Platform Toggle Switch Input
Status of Ground/Platform Toggle Switch Input
Status of Ground/Platform Toggle Switch Input
Status of Platform Toggle Switch Input
[Platform Mode = TRUE]
Status of Creep Switch Input
[Platform Mode = TRUE]
Status of Platform Switch Input
[Platform Mode = TRUE]
Status of Platform SkyGuard Override Switch Input if
MACHINE SETUP
Status of MSSO switch;
[MACHINE SETUP'MARKET=CE and Ground mode = TRUE]
Status of Platform Toggle Switch Input
[Platform Mode = TRUE and MACHINE SETUP ' H&T LIGHTS = YES]
UGM Nite Brite Relay Enable output
[Platform Mode = TRUE and MACHINE SETUP ' H&T LIGHTS = YES]
SkyGuard Input #1 (PLT J7-18) AND SkyGuard Input #2 (PLT J1-23)
state
[Platform Mode = TRUE and MACHINE SETUP ' SKYGUARD ? NO]
State of SkyGuard Platform Input #1 (J7-18); relay NC contacts - closed
when active
[Platform Mode = true and MACHINE SETUP ' SKYGUARD ? NO]
State of SkyGuard Platform Input #2 (J1-23); relay NC contacts - closed
when active
[Platform Mode= TRUE and MACHINE SETUP ' SKYGUARD ? NO]
State of softtouch input (Platform input J1-20)
[MACHINE SETUP ' SOFTTOUCH = YES]
Description
SKYGUARD = YES
3121714

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450aM450ajE450aj

Table of Contents