DTC Cat
DTC Num
22
19
L/S JOY. OUT OF RANGE HIGH
22
20
L/S JOY. CENTER TAP BAD
22
21
LIFT/SWING LOCKED - JOYSTICK MOVED
BEFORE FOOTSWITCH
22
22
WAITING FOR FSW TO BE OPEN
22
23
FUNCTION SWITCHES LOCKED - SELECTED
BEFORE ENABLE
22
45
FUNCTION PROBLEM - JIB SWING LEFT PERMA-
NENTLY SELECTED
22
46
FUNCTION PROBLEM - JIB SWING RIGHT PER-
MANENTLY SELECTED
22
47
FUNCTION PROBLEM - PLATFORM ROTATE LEFT
PERMANENTLY SELECTED
22
48
FUNCTION PROBLEM - PLATFORM ROTATE
RIGHT PERMANENTLY SELECTED
22
49
FUNCTION PROBLEM - JIB LIFT UP PERMA-
NENTLY SELECTED
22
50
FUNCTION PROBLEM - JIB LIFT DOWN PERMA-
NENTLY SELECTED
22
51
FUNCTION PROBLEM - TELESCOPE IN PERMA-
NENTLY SELECTED
22
52
FUNCTION PROBLEM - TELESCOPE OUT PERMA-
NENTLY SELECTED
22
57
FUNCTION PROBLEM - TOWER LIFT UP PERMA-
NENTLY SELECTED
22
58
FUNCTION PROBLEM - TOWER LIFT DOWN PER-
MANENTLY SELECTED
22
62
FUNCTION PROBLEM - PLATFORM LEVEL UP
PERMANENTLY SELECTED
22
63
FUNCTION PROBLEM - PLATFORM LEVEL
DOWN PERMANENTLY SELECTED
3121714
Table 6-17. Diagnostic Trouble Codes
DTC Text
The PM detects that the Lift or Swing joystick sig-
nal voltage > 8.1V and reports the fault to the
UGM.
The PM detects that the Lift or Swing center tap
voltage is not between 3.31 volts and 3.75 volts
and reports the fault to the UGM
The machine is in Platform Mode and the Lift and/
or Swing controls are not in the neutral position
immediately following Start Up -OR- The
machine is in Platform Mode and a proper
machine enable signal is received or DTC 2212,
2213 or 2223 is active while the Lift/Swing joy-
stick is not in the neutral position.
Machine is in Platform Mode AND Footswitch has
been engaged since Start Up
The machine is in Platform Mode and a proper
machine enable signal is received or DTC 2212,
2213 or 2221 is active while any of the following
boom control inputs are engaged: AWDA Enable,
Tower Lift, Telescope, Platform Level, Platform
Rotate, Jib Lift (if MACHINE SETUP -> JIB = YES)
and Jib Rotate (if MACHINE SETUP -> JIB PLUS =
YES)
The machine is in Platform mode and the Jib Swing
Left input = High at Startup
The machine is in Platform mode and the Jib Swing
Right input = High at Startup
The machine is in Platform mode and the Platform
Rotate Left input = High at Startup
The machine is in Platform mode and the Platform
Rotate Right input = High at Startup
The machine is in Platform mode and the Jib Lift Up
input = High at Startup
The machine is in Platform mode and the Jib Lift
Down input = High at Startup
The machine is in Platform mode and the Telescope
In input = High at Startup
The machine is in Platform mode and the Telescope
Out input = High at Startup
The machine is in Platform mode and the Tower Lift
Up input = High at Startup
The machine is in Platform mode and the Tower Lift
Down input = High at Startup
The machine is in Platform mode and the Platform
Level Up input = High at Startup
The machine is in Platform mode and the Platform
Level Down input = High at Startup
SECTION 6 - JLG CONTROL SYSTEM
Fault Description
The PM detects that the lift/swing center tap
voltage is between 3.31 and 3.75 volts and no
longer reports the fault to the UGM
The PM detects that the lift/swing center tap
voltage is between 3.31 and 3.75 volts and no
longer reports the fault to the UGM
If triggered by the Lift/Swing controls not being
in the neutral position immediately following
Start Up, then when Lift/Swing controls are
returned to neutral and the machine is not in
the Enabled state.
If triggered by proper machine enable signal
being received while the Lift/Swing controls are
not in the neutral position, then when the Lift/
Swing controls are returned to neutral or the
footswitch is released
Footswitch is disengaged
None of the boom controls that trigger this fault
are engaged or the Footswitch is disengaged.
Jib Swing Left input = LOW while the machine is
not Enabled
Jib Swing Right input = LOW while the machine
is not Enabled
Platform Rotate Left input = LOW while the
machine is not Enabled
Platform Rotate Right input = LOW while the
machine is not Enabled
Jib Lift Up input = LOW while the machine is not
Enabled
Jib Lift Down input = LOW while the machine is
not Enabled
Telescope In input = LOW while the machine is
not Enabled
Telescope Out input = LOW while the machine is
not Enabled
Telescope Out input = LOW while the machine is
not Enabled
Tower Lift Down input = LOW while the machine
is not Enabled
Platform Level Up input = LOW while the
machine is not Enabled
Platform Level Down input = LOW while the
machine is not Enabled
Solution
6-71