Message Displayed on
Analyzer
RUNNING
TESTING VALVES
3121714
Table 6-11. System Test Messages
Message Displayed on
Analyzer
CHECK GROUND/ PLATFORM SELECT
CHECK CAN WIRING
BATTERY VOLTAGE TOO LOW
BATTERY VOLTAGE TOO HIGH
CHECK SPEED
HIGH TILT ANGLE
OPEN FOOTSWITCH
CLOSE FOOTSWITCH
BAD FOOTSWITCH
OPEN FOOTSWITCH
PLATFORM OVERLOADED
CLOSE FOOTSWITCH
OPEN FOOTSWITCH
PRESS AND HOLD FOOTSWITCH
LIFT BYPASS VALVE (E400
OPEN FOOTSWITCH
FLOW CTRL VALVE
PRIORITY BYPASS (E400)
STEER RIGHT
STEER LEFT
SWING LEFT
SWING RIGHT
SWING ASSIST VALVE (E400)
LIFT UP
LIFT DOWN
TELESCOPE OUT
TELESCOPE IN
TOWER UP (E300, E400)
TOWER DOWN (E300, E400)
JIB UP
JIB DOWN
JIB LT VALVE
JIB RT VALVE
PLATFORM LT VALVE
SECTION 6 - JLG CONTROL SYSTEM
Initial display when system test is run while running certain "critical" checks are made.
The analyzer must be connected to the active control station to run the system test
The system test cannot run unless the CAN Bus is operating properly
The system test cannot run with MTM-reported battery voltage below 39.5V (not UGM-compen-
sated value)
The system test cannot run with the MTM-reported battery voltage above 65V
Reported vehicle speed must = 0 Hz (or mph)
The vehicle is tilted > 3° or the tilt sensor if faulty
In platform mode, the footswitch must be open at the start of the test.
In platform mode, the operator must close the footswitch when this message is displayed
The two footswitch signals are not changing together, probably because one is open circuit. Check
footswitch and wiring.
In platform mode, the operator must open the footswitch when this message is displayed.
Load Sensing is configured and the ground module considers the platform to be overloaded
*Check for Footswitch closed
*Wait for Footswitch to open
*The operator must engage and hold the footswitch for the next batch of tests to be successful.
This is due to the hardware high side driver cutout in the ground module
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
*Wait for Footswitch to open the advance
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT; or SHORT TO GROUND (or advance test after short delay) do
not energize for E300
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT; or SHORT TO GROUND (or advance test after short delay). do
not energize for E300
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT (or advance test after short delay)
SHORT TO BATTERY or OPEN-CIRCUIT or SHORT TO GROUND (or advance test after short delay)