Brother GTX-4 Service Manual page 434

Hide thumbs Also See for GTX-4:
Table of Contents

Advertisement

Error
Error message
5260
[Machine Error]
5301
[Machine Error]
5302
[Machine Error]
5303
[Machine Error]
5304
[Machine Error]
5305
[Machine Error]
5306
[Machine Error]
5307
[Machine Error]
Description
There is no compatibility in
version between the main
circuit board firmware and the
maintenance circuit board
firmware.
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
The error in communication
with the main circuit board
was detected by the
maintenance unit (color).
8-17
Remedy
Update the firmware to the newest one. If the
updating operation is interrupted in the process (for
any reason like blackout), redo the operation from
scratch to complete it properly.
(1) After reactivating the GTX, wait and see the
situation if it operates without any error.
(2) There is a possibility that this error occurred
collaterally after any other error had occurred.
Acquire the log file and use the GTX4 Service Tool
(View the DataLog -> Check Operation) to check
to see if another error occurs before or after this
error log.