Removing the Operator's Platform (continued)
Outcross 9060
18234SL Rev B
To prevent damage to the electrical wire harnesses, coolant hoses,
and refrigerant hoses, numerous cable ties and clamps are used
to secure these items to the machine. Record the location of all
cable ties and clamps that are removed from the machine during
operator platform removal so that they can be properly replaced
during installation.
g255047
1.
Access panel
2.
Battery negative (-) cable
3.
Battery negative (+) cable
6. Remove the access panel from the right side of the control console.
7. Disconnect the battery positive (+) and negative (-) cables from the terminal
bracket posts.
8. Disconnect the hoses at the hydraulic manifold ST and LS/OR1 ports. Cap
the fittings and plug the hoses to prevent contamination from entering the
hydraulic system.
IMPORTANT
Figure 135
4.
Hydraulic manifold ST port
5.
Hydraulic manifold LS/OR1 port