Traction Charge Circuit (continued)
Outcross 9060
18234SL Rev B
charge pressure is limited to 2,000 kPa (290 psi) in the pump by a relief valve
located in the tandem piston (traction) pump. Charge pressure at each traction
(piston) pump can be viewed while the vehicle is stationary using the InfoCenter
SERVICE–TRACTION–TRACTION INPUTS–FRONT TRACTION and REAR
TRACTION readings. Charge pressure can also be measured at the charge
pressure test port located near the charge filter assembly. Measured pressure
should be approximately 2,068 kPa (300 psi).
Page 5–17
Hydraulic System: Hydraulic Flow Diagrams