Toro Outcross 9060 Service Manual page 181

Table of Contents

Advertisement

Removing the Main Hydraulic Manifold (continued)
Installing the Main Hydraulic Manifold
Outcross 9060
18234SL Rev B
1. Remove the operator's platform; refer to
(page
8–6).
2. To prevent contamination of hydraulic system during manifold removal,
thoroughly clean exterior of manifold and fittings.
3.
Label and disconnect wire harness connectors from the solenoid valves.
4. Label and disconnect the hydraulic lines from the manifold and put caps or
plugs on open hydraulic lines and fittings to prevent system contamination.
5. Remove the main manifold from the machine.
6. If hydraulic fittings are to be removed from the manifold, mark the fitting
orientation to allow for correct assembly. Remove the fittings from the
manifold and discard the O−rings.
Note: The main hydraulic manifold is aluminum.
1. Lubricate new O-rings and place them onto the fittings. If previously
removed, install the fittings into the manifold ports using alignment marks
made during removal; refer to
Thread O-Ring Fittings) (page
2. Position the manifold to the frame and secure with 4 cap screws.
3. Remove the caps and plugs from the fittings and hoses. Properly connect
the hydraulic lines to the manifold; refer to
Tubes (O-Ring Face Seal) (page
4. Connect the wire harness connectors to the cartridge valve solenoids.
5. Install the operator's platform; refer to
(page
8–13).
Removing the Operator's Platform
Installing the Hydraulic Fittings (SAE Straight
5–10).
Installing Hydraulic Hoses and
5–8).
Installing the Operator's Platform
Page 5–85
Hydraulic System: Service and Repairs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

07511ba07511ca07511aa07511da

Table of Contents