Testing Relays with 5 Terminals (continued)
Electrical System: Electrical Component Testing
make and break continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
6. Connect multimeter (ohms setting) leads to relay terminals 30 and 87A. Apply
+12 VDC to terminal 85. The relay should make and break continuity between
terminals 30 and 87A as +12 VDC is applied and removed from terminal 85.
7. Replace the relay as necessary.
8. If the relay tests correctly and a circuit problem still exists, check the wire
harnesses; refer to
9. Connect the wire harness, install any items removed to access the relay, and
connect the battery ground cable.
Appendix A (page
A–1).
Page 6–68