Ext. Closed Loop - Danfoss VLT AQUA Drive FC 200 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

How to Programme the Low Ha...

6.4.18 21-** Ext. Closed Loop

Par. No. #
21-0* Ext. CL Autotuning
21-00
21-01
21-02
21-03
21-04
21-09
21-1* Ext. CL 1 Ref./Fb.
21-10
6
6
21-11
21-12
21-13
21-14
21-15
21-17
21-18
21-19
21-2* Ext. CL 1 PID
21-20
21-21
21-22
21-23
21-24
21-3* Ext. CL 2 Ref./Fb.
21-30
21-31
21-32
21-33
21-34
21-35
21-37
21-38
21-39
21-4* Ext. CL 2 PID
21-40
21-41
21-42
21-43
21-44
21-5* Ext. CL 3 Ref./Fb.
21-50
21-51
21-52
21-53
21-54
21-55
21-57
21-58
21-59
122
Parameter description
Closed Loop Type
PID Performance
PID Output Change
Minimum Feedback Level
Maximum Feedback Level
PID Auto Tuning
Ext. 1 Ref./Feedback Unit
Ext. 1 Minimum Reference
Ext. 1 Maximum Reference
Ext. 1 Reference Source
Ext. 1 Feedback Source
Ext. 1 Setpoint
Ext. 1 Reference [Unit]
Ext. 1 Feedback [Unit]
Ext. 1 Output [%]
Ext. 1 Normal/Inverse Control
Ext. 1 Proportional Gain
Ext. 1 Integral Time
Ext. 1 Differentation Time
Ext. 1 Dif. Gain Limit
Ext. 2 Ref./Feedback Unit
Ext. 2 Minimum Reference
Ext. 2 Maximum Reference
Ext. 2 Reference Source
Ext. 2 Feedback Source
Ext. 2 Setpoint
Ext. 2 Reference [Unit]
Ext. 2 Feedback [Unit]
Ext. 2 Output [%]
Ext. 2 Normal/Inverse Control
Ext. 2 Proportional Gain
Ext. 2 Integral Time
Ext. 2 Differentation Time
Ext. 2 Dif. Gain Limit
Ext. 3 Ref./Feedback Unit
Ext. 3 Minimum Reference
Ext. 3 Maximum Reference
Ext. 3 Reference Source
Ext. 3 Feedback Source
Ext. 3 Setpoint
Ext. 3 Reference [Unit]
Ext. 3 Feedback [Unit]
Ext. 3 Output [%]
MG20T202 - VLT
VLT AQUA Low Harmonic Drive Operating Instructions
Default value
[0] Auto
[0] Normal
0.10 N/A
-999999.000 N/A
999999.000 N/A
[0] Disabled
[0]
0.000 ExtPID1Unit
100.000 ExtPID1Unit
[0] No function
[0] No function
0.000 ExtPID1Unit
0.000 ExtPID1Unit
0.000 ExtPID1Unit
0 %
[0] Normal
0.50 N/A
20.00 s
0.00 s
5.0 N/A
[0]
0.000 ExtPID2Unit
100.000 ExtPID2Unit
[0] No function
[0] No function
0.000 ExtPID2Unit
0.000 ExtPID2Unit
0.000 ExtPID2Unit
0 %
[0] Normal
0.50 N/A
20.00 s
0.00 s
5.0 N/A
[0]
0.000 ExtPID3Unit
100.000 ExtPID3Unit
[0] No function
[0] No function
0.000 ExtPID3Unit
0.000 ExtPID3Unit
0.000 ExtPID3Unit
0 %
®
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion
operation
index
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-2
2 set-ups
TRUE
-3
2 set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
0
Type
Uint8
Uint8
Uint16
Int32
Int32
Uint8
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32

Advertisement

Table of Contents
loading

Table of Contents