6 How to Programme the Low Harmonic Drive
6.1 How to Programme the Frequency
Converter
The parameters are grouped into various parameter groups
for easy selection of the correct parameter for optimized
frequency converter operation.
Overview of parameter groups
6
6
Group
0-**
1-**
2-**
3-**
4-**
5-**
6-**
8-**
9-**
10-**
13-**
14-**
15-**
16-**
18-**
20-**
21-**
22-**
23-**
24-**
25-**
26-**
27-**
29-**
30-**
31-**
Table 6.1 Parameter Groups
Parameter descriptions and selections are displayed on the
graphic (GLCP) or numeric (NLCP) in the display area. (See
5 How to Operate the Low Harmonic Drive for details.)
Access the parameters by pressing the [Quick Menu] or
66
Title
Operation / Display
Load / Motor
Brakes
Reference / Ramps
Limits / Warnings
Digital In/Out
Analog In/Out
Communication and Options
Profibus
DeviceNet Fieldbus
Smart Logic
Special Functions
Drive Information
Data Readouts
Info and Readouts
Drive Closed Loop
Extended Closed Loop
Application Functions
Time-based Functions
Application Functions 2
Basic Cascade Controller Functions
Analog I/0 Option MCB 109
Extended Cascade Control
Water Application Functions
Special Features
Bypass Option
MG20T202 - VLT
VLT AQUA Low Harmonic Drive Operating Instructions
Function
Parameters related to the fundamental functions of the frequency converter,
function of the LCP buttons and configuration of the LCP display.
Parameter group for motor settings.
Parameter group for setting brake features in the frequency converter.
Parameters for reference handling, definitions of limitations, and configuration of
the reaction of the frequency converter to changes.
Parameter group for configuring limits and warnings.
Parameter group for configuring the digital inputs and outputs.
Parameter group for configuration of the analog inputs and outputs.
Parameter group for configuring communications and options.
Parameter group for Profibus-specific parameters (requires profibus option).
Parameter group for DeviceNet-specific parameters (requires DeviceNet option).
Parameter group for Smart Logic Control
Parameter group for configuring special frequency converter functions.
Parameter group containing frequency converter information such as operating
data, hardware configuration and software versions.
Parameter group for data read-outs, e.g. actual references, voltages, control, alarm,
warning and status words.
This parameter group contains the last 10 Preventive Maintenance logs.
This parameter group is used for configuring the closed loop PID Controller that
controls the output frequency of the unit.
Parameters for configuring the three Extended Closed Loop PID Controllers.
These parameters monitor water applications.
These parameters are for actions needed to be performed on a daily or weekly
basis, e.g. different references for working hours/non-working hours.
Parameters for the Drive Bypass.
Parameters for configuring the Basic Cascade Controller for sequence control of
multiple pumps.
Parameters for configuring the Analog I/0 Option MCB 109.
Parameters for configuring the Extended Cascade Control (MCO 101/MCO 102).
Parameters for setting water specific functions.
Parameters for configuring the brake resistor value.
Parameters for configuring the Bypass Option (MCO 104).
[Main Menu] key on the control panel. The quick menu is
used primarily for commissioning the unit at start-up by
providing those parameters necessary to start operation.
®