6.5.2 5-** Digital In/Out

Par.
Parameter description
No. #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
6
6
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-19
Terminal 37 Safe Stop
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 Digital Output
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay

6.5.3 8-** Comm. and Options

Par.
Parameter description
No. #
8-0* General Settings
8-01
Control Site
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-5* Digital/Bus
8-53
Start Select
8-55
Set-up Select
134
VLT AQUA Low Harmonic Drive Operating Instructions
Default value
[0] PNP
[0] Input
[0] Input
[8] Start
[0] No operation
[0] No operation
[0] No operation
[90] AC Contactor
[91] DC Contactor
[0] No operation
[0] No operation
[0] No operation
[1] Safe Stop Alarm
[0] No operation
[0] No operation
[0] No operation
0.30 s
0.30 s
Default value
[0] Digital and ctrl.word
null
1.0 s
[0] Off
[1] Resume set-up
[0] Do not reset
[1] FC MC
2 N/A
[2] 9600 Baud
10 ms
5000 ms
25 ms
[3] Logic OR
[3] Logic OR
®
MG20T202 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
Type
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-3
Uint16
-3
Uint16
-3
Uint16
-
Uint8
-
Uint8