How to Programme the Low Ha...
6.4.14 15-** FC Information
Par. No. #
15-0* Operating Data
15-00
15-01
15-02
15-03
15-04
15-05
15-06
15-07
6
6
15-08
15-1* Data Log Settings
15-10
15-11
15-12
15-13
15-14
15-2* Historic Log
15-20
15-21
15-22
15-23
15-3* Alarm Log
15-30
15-31
15-32
15-33
15-34
15-35
15-36
15-37
15-4* Drive Identification
15-40
15-41
15-42
15-43
15-44
15-45
15-46
15-47
15-48
15-49
15-50
15-51
15-53
15-6* Option Ident
15-60
15-61
15-62
15-63
116
Parameter description
Operating Hours
Running Hours
kWh Counter
Power Up's
Over Temp's
Over Volt's
Reset kWh Counter
Reset Running Hours Counter
Number of Starts
Logging Source
Logging Interval
Trigger Event
Logging Mode
Samples Before Trigger
Historic Log: Event
Historic Log: Value
Historic Log: Time
Historic Log: Date and Time
Alarm Log: Error Code
Alarm Log: Value
Alarm Log: Time
Alarm Log: Date and Time
Alarm Log: Setpoint
Alarm Log: Feedback
Alarm Log: Current Demand
Alarm Log: Process Ctrl Unit
FC Type
Power Section
Voltage
Software Version
Ordered Typecode String
Actual Typecode String
Frequency Converter Ordering No
Power Card Ordering No
LCP Id No
SW ID Control Card
SW ID Power Card
Frequency Converter Serial Number
Power Card Serial Number
Option Mounted
Option SW Version
Option Ordering No
Option Serial No
MG20T202 - VLT
VLT AQUA Low Harmonic Drive Operating Instructions
Default value
0 h
0 h
0 kWh
0 N/A
0 N/A
0 N/A
[0] Do not reset
[0] Do not reset
0 N/A
0
ExpressionLimit
[0] False
[0] Log always
50 N/A
0 N/A
0 N/A
0 ms
ExpressionLimit
0 N/A
0 N/A
0 s
ExpressionLimit
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0 %
[0]
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
®
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
74
Uint32
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint32
-
Uint16
-3
TimD
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint32
-3
Uint32
0
TimeOfDay
0
Uint16
0
Int16
0
Uint32
0
TimeOfDay
-3
Int32
-3
Int32
0
Uint8
-
Uint8
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[5]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[8]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[10]
0
VisStr[19]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[18]
Need help?
Do you have a question about the VLT AQUA Drive FC 200 and is the answer not in the manual?