How To Programme The Active Filter - Danfoss VLT AQUA Drive FC 200 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

How to Programme the Low Ha...
The following parameter groups are accessible:
Group no.
Parameter group:
0-**
Operation/Display
1-**
Load/Motor
2-**
Brakes
3-**
References/Ramps
4-**
Limits/Warnings
5-**
Digital In/Out
6-**
Analog In/Out
8-**
Comm. and Options
9-**
Profibus
10-**
CAN Fieldbus
11-**
LonWorks
13-**
Smart Logic
14-**
Special Functions
15-**
FC Information
16-**
Data Readouts
18-**
Data Readouts 2
20-**
FC Closed Loop
21-**
Ext. Closed Loop
22-**
Application Functions
23-**
Time Actions
25-**
Cascade Controller
26-**
Analog I/O Option MCB 109
27-**
Cascade CTL Option
29-**
Water Application Functions
31-**
Bypass Option
After selecting a parameter group, choose a parameter by
means of the navigation keys.
Overview of parameter groups for the filter part
Group
Title
0-
Operation / Display
5-
Digital In/Out
8-
Communication and Options
14-
Special Functions
15-
Unit Information
16-
Data Readouts
300-
AF Settings
301-
AF Readouts
Table 6.3 Parameter groups
A list of all parameters accessible from the filter LCP can
be found in the section Parameter Options - Filter. A more
detailed description of the active filter parameters can be
found in the VLT Active Filter AAF005 Manual, MG90VXYY
VLT AQUA Low Harmonic Drive Operating Instructions
The middle section on the GLCP display shows the
parameter number and name as well as the selected
parameter value.
Illustration 6.3 Display Example

6.2 How to Programme the Active Filter

The factory settings for the filter part of the Low Harmonic
Drive are chosen for optimal operation with a minimum of
additional programming. All CT-values, as well as
frequency, voltage levels and other values directly linked
to the drive configuration are pre-set.
It is not recommended to change any other parameters
influencing the filter operation. However, selection of read-
outs and what information to be displayed on the LCP
status lines can be made to fit individual preferences.
To set up the filter two steps are necessary:
Function
Parameters related to the fundamental functions of the filter, function of the LCP
buttons and configuration of the LCP display.
Parameter group for configuring the digital inputs and outputs.
Parameter group for configuring communications and options.
Parameter group for configuring special functions.
Parameter group containing active filter information such as operating data,
hardware configuration and software versions.
Parameter group for data read-outs, e.g. actual references, voltages, control, alarm,
warning and status words.
Parameter group for setting the Active Filter. Apart from 300-10 Active Filter
Nominal Voltage, it is not recommended to change the settings of this parameter
group
Parameter group for the filter readouts.
®
MG20T202 - VLT
is a registered Danfoss trademark
740RPM
Basic Settings
0 -01 Language
[0] English
Change the nominal voltage in 300-10 Active Filter
Nominal Voltage
Make sure the filter is in auto mode (press [Auto
On])
10.64A
1 [1]
0-0 *
6
71
6