Analog I/O Option Mcb - Danfoss VLT AQUA Drive FC 200 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

How to Programme the Low Ha...

6.4.22 26-** Analog I/O Option MCB 109

Par. No. #
Parameter description
26-0* Analog I/O Mode
26-00
Terminal X42/1 Mode
26-01
Terminal X42/3 Mode
26-02
Terminal X42/5 Mode
26-1* Analog Input X42/1
26-10
Terminal X42/1 Low Voltage
26-11
Terminal X42/1 High Voltage
26-14
Term. X42/1 Low Ref./Feedb. Value
26-15
Term. X42/1 High Ref./Feedb. Value
26-16
Term. X42/1 Filter Time Constant
26-17
Term. X42/1 Live Zero
26-2* Analog Input X42/3
26-20
Terminal X42/3 Low Voltage
26-21
Terminal X42/3 High Voltage
26-24
Term. X42/3 Low Ref./Feedb. Value
26-25
Term. X42/3 High Ref./Feedb. Value
26-26
Term. X42/3 Filter Time Constant
26-27
Term. X42/3 Live Zero
26-3* Analog Input X42/5
26-30
Terminal X42/5 Low Voltage
26-31
Terminal X42/5 High Voltage
26-34
Term. X42/5 Low Ref./Feedb. Value
26-35
Term. X42/5 High Ref./Feedb. Value
26-36
Term. X42/5 Filter Time Constant
26-37
Term. X42/5 Live Zero
26-4* Analog Out X42/7
26-40
Terminal X42/7 Output
26-41
Terminal X42/7 Min. Scale
26-42
Terminal X42/7 Max. Scale
26-43
Terminal X42/7 Bus Control
26-44
Terminal X42/7 Timeout Preset
26-5* Analog Out X42/9
26-50
Terminal X42/9 Output
26-51
Terminal X42/9 Min. Scale
26-52
Terminal X42/9 Max. Scale
26-53
Terminal X42/9 Bus Control
26-54
Terminal X42/9 Timeout Preset
26-6* Analog Out X42/11
26-60
Terminal X42/11 Output
26-61
Terminal X42/11 Min. Scale
26-62
Terminal X42/11 Max. Scale
26-63
Terminal X42/11 Bus Control
26-64
Terminal X42/11 Timeout Preset
VLT AQUA Low Harmonic Drive Operating Instructions
Default value
[1] Voltage
[1] Voltage
[1] Voltage
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
®
MG20T202 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-3
Int32
-3
Int32
6
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
129
6