Configuration Using the Web Interface
Port Event
Link-Up
Link-Down
Both
PoE Powering Event
Enable
PoE Powering Event
Disable
Apply

SysLog Configuration

The System Log provides the system administrator ES7506 events history. There are two System Log modes
provided by the ES7506, Local mode and Remote mode.
Warning - SysLog Configuration Page
Syslog Mode
Remote IP Address
Apply
When enabling Local or Both modes, you can monitor the system logs in the Monitor and Diag /Event Log
page.
84 - SysLog Configuration
The port is connected to another device.
The port is disconnected. For example, the cable is pulled out or the opposing
devices is down.
The link status changed.
The PoE port is powering.
Warning Event is sent when.....
The PoE port is not powering.
Click Apply to apply the settings.
Note: You must Save the settings
settings if the ES7506 is powered off.
There are two system logs available:
Local Mode: The ES7506 prints the events that have been
selected in the Event Selection page to the System Log table of
the ES7506. You can monitor the system logs in the Monitor
and Diag /Event Log page.
Remote Mode: Assign the IP address of the System Log server.
The ES7506 sends the events that occurred in the selected in
Event Selection page to System Log server that you assign.
Both: This enables both Local and Remote modes.
The IP address of the System log server.
Click Apply to apply the settings.
Note: You must Save the settings
maintain these settings if the ES7506 is powered off.