68 - Redundant Ring - Comtrol RocketLinx ES7506 User Manual

Industrial managed poe switch 4 - fast ethernet poe ports 2 - fast ethernet uplink ports
Hide thumbs Also See for RocketLinx ES7506:
Table of Contents

Advertisement

Configuration Using the Web Interface
Redundant Ring
The most common industrial network redundancy is to form a ring or loop. Typically, managed switches are
connected in series and the last switch is connected back to the first one. In such connection, you can
implement Redundant Ring technology. The ES7506 can only create a single ring.
Redundant Ring Page
To create a Redundant Ring enter the Ring ID, which has range from 0 to 31. If the name
New Ring
field is left blank, the name of this ring is automatically named with the Ring ID. The
maximum number of rings is 32.
(Ring ID/Name)
Note: Once a ring is created, you cannot change it.
Ring Configuration
Once a Ring is created, the Ring ID appears, and cannot be changed. In multiple ring
ID
environments, the traffic can only be forwarded under the same Ring ID. Remember to
check the Ring ID when there are more than one ring in existence.
This field shows the name of the Ring. If it is not entered when creating, it is
Name
automatically named by the rule RingID.
Version
The version of Ring can be changed here, the choices are Rapid Super Ring or Super Ring.
The switch with highest priority (highest value) is automatically selected as the Ring
Master (RM). When one of the ring ports on this switch becomes a forwarding port and the
Device Priority
other one becomes a blocking port. If all of the switches have the same priority, the switch
with the highest MAC address is selected as the Ring Master.
In a Rapid Super Ring environment, you should have two Ring ports. Whether this switch
is a Ring Master or not. When configuring Rapid Super Rings, two ports should be selected
Ring Port1
to be Ring ports. For a Ring Master, one of the Ring Ports becomes the forwarding port
and the other one becomes the blocking port.
Change the Path Cost of Ring Port1, if this switch is the Ring Master of a Ring, then it
determines the blocking port. The port with higher Path Cost in the two Ring Ports
Path Cost
becomes the blocking port, If the Path Cost is the same, the port with larger port number
becomes the blocking port.
Ring Port2
Assign another port for ring connection.
Path Cost
Change the Path Cost of Ring Port2.

68 - Redundant Ring

RocketLinx ES7506 User Guide: 2000529 Rev. F