RSTP Info (cont)
Switch# show spanning-tree summary
Rapid Spanning-Tree feature
Spanning-Tree BPDU transmission-limit
Root Address
Root Path Cost : 400000
Root Times :
Bridge Address
Bridge Times : max-age 20 sec, hello-time
BPDU skewing detection disabled for the bridge
Backbonefast disabled for bridge
Topology change flag not set, detected flag not set
Number of topology changes 313, last change occurred from
RSTP Summary
0000.0000.0000
Timers: hello 0 , topology change 0
Summary of connected spanning tree ports :
Port-State Summary
Blocking
--------
Port Link-Type Summary
AutoDetected
------------
Switch# show spanning-tree port detail fa7
Rapid Spanning-Tree feature
Port 128.6 as Disabled Role is in Disabled State
Port Path Cost 200000, Port Identifier 128.6
RSTP Port Admin Link-Type is Auto, Oper Link-Type is Point-to-Point
RSTP Port Admin Edge-Port is Enabled, Oper Edge-Port is Edge
Designated root has priority 32768, address 00c0.4e2D.0112
Port Info
Designated bridge has priority 32768, address 00c0.4e2D.1aec
Designated Port ID is 128.6, Root Path Cost is 600000
Timers : message-age 0 sec, forward-delay 0 sec
BPDU: sent 43759 , received 4854
TCN : sent 0 , received 0
Forwarding-State Transmit count
Message-Age Expired count
RocketLinx ES7506 User Guide: 2000529 Rev. F
00c0.4e2D.004f
max-age 20 sec, hello-time
00c0.4e2D.0008
Listening
Learning
---------
--------
1
0
PointToPoint
------------
6
Configuration Using the Command Line Interface (CLI)
Enabled
3
Priority 32768
Root Port : 6
2 sec, forward-delay 15 sec
Priority 32768
2 sec, forward-delay 15 sec
Forwarding
----------
0
1
SharedLink
----------
0
0
(Interface_ID)
Enabled
12
Disabled
--------
4
EdgePort
--------
4