Cp-215 Communications Port Settings - YASKAWA MP920 User Manual

Machine controller
Table of Contents

Advertisement

4.2.2

CP-215 Communications Port Settings

Setting CP-215PC/AT Cards
CP-215 PC/AT Cards are set when engineering is performed with the MPE720 via the 215IF.
Install the card in an unused ISA slot of the personal computer.
Refer to the setting example given below.
Setting Example
Shared memory address: 0CC000H
Interrupt level: IRQ11
215IF/AT F87215-90000-S01
Jumper lead
* 1. Specify the value of the third digit of the shared memory address
DIP switch (pins 1 to 4)
SW1
ON
OFF
1 2 3 4
Plug switch (1 to 8)
F
F
SW2
SW3
SW4
Rotary switches (setting 0 to F)
according to the combinations of pins 1 and 2 of the DIP switch as
shown below.
Shared Memory Address
(
0000-
3FFF) H
(
4000-
7FFF) H
(
8000-
BFFF) H
(
C000-
FFFF) H
4-7
4.2 Communications Port Settings
LED1
LED2
LED
LED3
LED4
0 C C 0 0 0 H
Pin 1
Pin 2
ON
ON
ON
OFF
OFF
ON
OFF
OFF