4 Communications Process
4.2.2 CP-215 Communications Port Settings
ii) Own Network Address (Network No.)
Set the number of the network to which the MPE720 is connected. Set the net-
work number to 1 when there is only one network segment.
iii) Max Connect Station (Maximum Number of Stations Connected)
Set the number of CP-215 network stations. The number of stations is the number
of 215IF Modules installed in all the Machine Controllers plus the number of Pro-
gramming Devices with 215 IF/AT Cards installed.
iv) Token Round Time Setting (Token Cycle Time)
Set to 100 for the target time from when each station receives the token until the
next time the token is received.
v) MEMOBUS Response Watch Time (MEMOBUS Response Monitoring Time)
Set to 255 for the time from when a message is transmitted until a response is
received.
c) Channel Tab Page
Set the number of panel command channels to 2. Leave the other parameters on their
default settings, as they are not used by the MPE720. Click the OK button when the
settings have been completed.
3. The Logical Port Setting Window will be displayed again. Click the OK button once
more. The display will return to the Communications Process Window. Check that CP-
215 has been allocated to logical port 2.