A.1.3 Parameter Details - YASKAWA MP920 User Manual

Machine controller
Table of Contents

Advertisement

Appendix A System Functions

A.1.3 Parameter Details

Remote Station Number (PARAM02)
Remote
Remote
Device
Station
Number
CP-215
1 to 64
00FFH
CP-216
1 to 30
(MECHA-
TROLINK)
80H
CP-217
1 to 254
(Serial)
0100H
CP-218
1 to 20
Function Code (PARAM04)
Set the MEMOBUS function code to be sent.
Function
Code
00H
Not used.
01H
Coil status read
02H
Input relay status read
03H
Holding register read
04H
Input register read
05H
Single coil status change
06H
Single holding register write
07H
Not used.
08H
Loopback test
09H
Holding register read (extended)
0AH
Input register read (extended)
0BH
Holding register write (extended)
0CH
Not used.
0DH
Discontinuous holding register read
(extended)
0EH
Discontinuous holding register write
(extended)
0FH
Multiple coil status change
10H
Multiple holding register write
11H to 20H
Not used.
21H to 30H
Reserved by system.
31H
MELSEC fixed buffer communications
32H
MELSEC random buffer read
Message is sent to the designated station.
Message is sent to all stations (broadcasting).
Message is sent to the designated station. (Message can be sent only
from the master station.)
Message is sent to the master station. (Message can be sent only
from salve stations.)
Message is sent to the station with the specified device address.
"0100H" must be specified if the device address of the remote sta-
tion is 0.
Message is sent to the station with the specified connection number.
Meaning
A-6
Meaning
215IF, 218IF,
217IF,
MECHA-
Serial*
TROLINK*
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
218IF only
No
218IF only
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents