Environmental Conditions
Item
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Vibration Resistance
Shock Resistance
Ground
Structure
Item
Ground
Dimensions
Cooling Method
Mass
Maximum Number of Repeaters that Can Be Connected
The maximum number of Repeaters that can be connected is as follows:
• For CP-215 communications: 8 Repeaters or less (Total transmission distance: 12 km
max.)
• For CP-216 communications : 2 Repeaters or less
(Total transmission distance for 1 Repeater: 600 m max. at 4 Mbps)
(Total transmission distance for 2 Repeaters: 350 m max. at 4 Mbps)
C
0 to 55°
5 to 95%RH (no condensation)
C
-25 to + 85°
5 to 95% (no condensation)
Conforming to JIS B 3502:
10 to 150 Hz with single-amplitude of 0.075 mm
57 to 150 Hz with fixed acceleration of 9.8 m/s
Conforming to JIS B 3502:
Peak acceleration of 147 m m/s
in the ±X, ±Y, and ±Z directions
Ground to 100 Ω max.
Panel mount type (mounting screws: M5× 4)
70 × 250 × 120 mm (W × H × D)
Natural cooling
1.6 kg
5-45
5.7 CP-215 Repeaters
Specifications
2
(1G)
2
(15G) twice for 11 ms each
Specifications
5