YASKAWA MP920 User Manual page 323

Machine controller
Table of Contents

Advertisement

Appendix D Wiring Communications
D.5.3 CP-215 Repeater Transmission Line Components
No.
Model (Manufactured by
Sumitomo Electric Industries,
1
CVS-EG-5/3002, L
2
CVS-EG-5/3002 with FC con-
nector at one end, L
3
CVS-EG-5/3002 with FC con-
nectors at both ends, L
4
2GI-C-V-NM, (EG-5/3002), L
5
2GI-GS-V-NM, (EG-5/3002),
*1
L
6
2GI-L-4C-LAP, (EG-5/3002)
7
2GI-C-LAP, (EG-5/3002), L
8
2GI-C-V-NM with FC connec-
tors at both ends, (EG-5/3002),
*3 *4
L
9
2GI-C-LAP, (EG-5/3002) with
FC connectors at both ends, L
*4
10
2GI-L-4C-LAP-MAZE, (EG-5/
*1
3002), L
11
2GI-L-4C-LAP-(with steel
pipe), (EG-5/3002), L
CP-215 Repeater-TS2 Transmission Line Components
Multi-mode Crystal Optical Fiber Cords and Cables for Short Wave-
length (850 nm)
Ltd.)
*1
In-panel single-core cord
In-panel single-core cord with FC
connector at one end
*2
In-panel single-core cord with FC
connectors at both ends
*2
*1
Indoor two-core cable (for racks
and troughs)
Indoor two-core cable (for racks,
troughs, and electrical conduits)
Outdoor two-core cable (for racks,
*1
troughs, and electrical conduits)
Outdoor two-core cable (for racks,
*1
troughs, and electrical conduits)
Indoor two-core cable with FC con-
nectors at both ends (for racks and
troughs)
Outdoor two-core cable with FC
connectors at both ends (for racks,
*3
troughs, and electrical conduits)
Two-core cable for vertical use
Two-core cable for underwater use
* 1. L is 100 m, 200 m, 500 m, or 1,000 m.
* 2. L is 0.3 m, 1 m, 3 m, or 5 m. For 10 m or longer, specify the cable
length in 5-m units.
* 3. L is 1 m, 3 m, or 5 m. For 10 m or longer, specify the cable length in 5-
m units.
* 4. A pulling eyelet can be mounted to protect optical connectors. To spec-
ify this option, append "-P" at the end of the model number.
Note: 1. If optical connectors or optical fiber cables are to be connected on-
site, specify a cable length that allows some play at both ends.
2. When ordering cords or cables with non-standard specifications,
refer to D.6.4 Specifying Detailed Order Patterns.
3. For ordering, contact your Yaskawa representative.
4. Be sure that excessive tensile force or lateral pressure will not be
applied to the cord.
5. For outdoor installation, specify LAP sheaths.
6. Cable sheath is made of PVC. If there is a risk of the cable being
exposed to oil or chemicals that may damage PVC, it is recom-
mended using cable sheaths made of polyethylene (PE).
Usage
Specification
No. in D.6.2
of this
Appendix
D-32
External Specifications, etc.
(1)
No sheath, cord only
(1)
No sheath
(1)
No sheath
(2)
Vinyl sheath, cable only
(3)
Polyethylene sheath, cable
only
(4)
LAP sheath, cable only
(5)
LAP sheath, cable only
(5)
LAP sheath
(5)
LAP sheath
-
Equipped with steel pipe
-
Equipped with steel pipe