5 215IF Module

5.5.5 Saving CP-215 Transmission Definitions Data

5.5.5
5.5.6
b) Link Status Data at the Local Station
F E DC B A 9 8 7 6 5 4 3 2 1 0
Fig. 5.4 Link Status Data (Local Station)
8. Station Name (Comment)
Displays the station name set in the Link Assignment Tab.

Saving CP-215 Transmission Definitions Data

Use the following procedure to save the CP-215 Transmission Definitions data.
In Online Mode, the settings are saved in the Machine Controller and the hard disk on the
computer. In Offline Mode, the settings are saved in the hard disk on the computer.
1. Click File (F) and then Save (S) on the CP-215 Transmission Definition Window's
menu.
2. Verify the message in the message box and click the Yes button.
3. Verify the message in the message box and click the OK button.

Deleting CP-215 Transmission Definitions Data

Use the following procedure to delete all of the CP-215 Transmission Definitions data. In
Online Mode, the data will be deleted from the Machine Controller and the hard disk on the
computer. In Offline Mode, the data will be deleted from the hard disk on the computer.
1. Click File (F) and then Delete (D) on the CP-215 Transmission Definition Window's
menu.
2. Verify the message in the message box and click the Yes button to delete the data.
MAC Status: LSI Error
MAC Status: CD Break
MAC Status: Reseved
MAC Status: Out of Ring (Token Not Received Timeout.)
Local Station Display
Reserved
Reserved
Reserved
PLC Model Code (Corresponds to the content of the "TYPE" column.)
02: CP-3500H
0D: CP-317
05: CP-316
11: ACGC4000
06: CP-916A
12: CP-517
0C: CP-9200SH
0E: CP-316H
14: MP920
16: CP-902
5-28
0F: CP-916G
C2: RIO-05
C5: RIO-2000
C6: RIO-120
62: 215IF/INV