5 215IF Module
5.5.4 Setting CP-215 Transmission Definitions
3. I/O Assignments
Assign bits to I/O for high-speed or low-speed scan.
• HI:
Input set for a high-speed scan.
• HO:
Output set for a high-speed scan.
• LI:
Input set for a low-speed scan.
• LO:
Output set for a low-speed scan.
To assign I/O, move the cursor to the desired position and click HI, HO, LI, or LO at the
bottom of the display. An I/O assignment can be deleted by moving the cursor to the
desired position and clicking DEL at the bottom of the display.
4. ST#
Displays the station number set in the I/O Assignment Tab.
5. TYPE
Displays the I/O device name set in the I/O Assignment Tab.
Limitations on Changing I/O Map Assignments
The settings made in advance in the Link Assignment Tab are assigned as defaults for the
high-speed scan I/O and low-speed scan I/O. The following limitations apply when chang-
ing I/O assignments.
• I/O assignments can be deleted. (For example, "LI" can be changed to ".")
• The scan speed designation can be changed. (For example, "LI" can be changed to
"HI.")
• The I/O designation cannot be changed. (For example, "LI" cannot be changed to "LO.")
Displaying the Link Status
The Status Tab displays the data that the 215IF is actually handling in link transmissions.
The tab only displays the settings; the settings cannot be changed.
2.
3.
4.
5.
6.
7.
8.
1. Configuration Information
Displays the CP-215 configuration information.
5-26