6.2.1 LOCAL (Pump Side) Start/Stop

a) START
Press the START button on the controller.
The Main Pump (MP) will start and the MP RUN lamp on the controller will light.
After this, the Booster Pump (BP) will start automatically and the B.P. RUN lamp on
the controller will light.
The current is indicated on the display during pump operation.
For other status display indications, refer to Table 6.1.
[ NOTE ]
b) STOP
Press the STOP button on the controller. The MP and BP will stop
simultaneously.
The RUN lamp goes out and the display gives a power reading of 0.0kW.

6.2.2 REMOTE Start/Stop

a) START
Enter the external "MP" start signal input from the control connector. The MP will
start.
In the case of DIP SW A-8 ⇒ OFF :
In the case of DIP SW A-8 ⇒ ON
The power is indicated on the display during pump operation.
status display indications, refer to Table 6.1.
[ NOTE ]
b) STOP
Interrupt the external MP start signal and the pump will stop.
PM10U
The pump will not start when an WARNING/ALARM has been
generated. When the START button is pressed, "STARTFAIL" will
appear on the display.
The pump will not start when a WARNING/ALARM has been
generated. When a START signal is entered, "STARTFAIL" will
appear on the display.
"MP" rotation reaches 3000 min-1, "BP"
will start automatically.
:
"MP" rotation reaches 3000 min-1, input
the external "BP" start signal. BP will start.
P.77